Wiring Device-Kellems Full Product Catalog

U SECTION

METAL AND NON-METALLIC RACEWAY

Wire Fill Capacity Chart and Technical Information

Non-Metallic Raceway Wire Fill Capacities Power (THHN/T90 Nylon)

Data (Copper Cables)

Data (Multimode Fiber Optic Cables)

Voice

14 AWG

12 AWG

10 AWG

Type RG59U

Cat. 5e

Cat. 6

Cat. 6A

Cat. 6 STP

(2) or (4) Fiber Round Cable

Fiber Optic Jumpers

Fiber Optic Zip Cord

4-Pair 25-Pair

Wire O.D. (in.):

0.111

0.13

0.164

0.19

0.41

0.242

0.21

0.25

0.35

0.29

0.19

0.118

.12 X .24 0.0288

Wire Area (sq. in.):

0.0097 0.0133 0.0211

0.0283 0.1320 0.0460 0.0346 0.0491

0.0962 0.0660

0.0283

0.0109

Channel Area (sq. in.)

Series

Channel

Wire Fill Capacity

40% 40% 40% 40% 40% 40% 40%

40%

40%

40%

PT1 PP1 PL1

A A A A

0.29 0.38 1.03 0.30 1.60 0.81 0.79 5.72 2.86 5.57 1.80 1.97 10.58

5

8

5 8

4 5

1 1

3 3 9 2

3 4

2 3 8 2

1

2 2 6 2

4 5

11

4 5

12

11

2 4

14 38

42

34 10 36 22 22 36 30 36 30 30 66 36 36

22

15

3 0 5 2 2

12

15

14

PW1

6

4

4

3

1

4

11

4

A+B

41 12 12

22 12 10 45 28 45 28 28 78 42 42

23

14

18

13

7 3 3

10

23

59 30 29

22

PW2 A B

A B

11 11

7 7

9 9

7 6

5 5

11 11

11 11

A+B

60 42 60 42 42 72 42 42

81

17

50 25 48 16 17 92 30 33

66 33 64 21 23

47 23 45 15 16 86 28

24 12 23

35 17 34

81

210 105 204

79 40 77 25 27

PB2 A B

A or B A+B+C A or C

40 79 25 28

9

40 79 25 28

17

PB3 A BC

5 6

7 8

11

66 72

B

12

A+B+C A or C

150

32 10

122

44

64 21 23

150

388 125 138

147

PS3 A BC

3.41 3.76

48 53

39 43

14 16

48 53

47

B 52 Note: Pathway (Raceway) fill shall be 40% maximum. Raceway fittings and outlets/receptacles reduce the cross section of the raceway system, thus reducing overall cable fill capacity. 11 31

Recommended Plate to Box Compatibility Selection Chart Non-Metallic Raceway Box Series PS3 Series

PB2 Series

PT12 & PW1 Series

PB3 Series

PDB12 Series

Sample Catalog Number

IND FCIB FCIB2G FCIB3G IND IND2G FCIB FCIB2G FCIB3G IND2G LP, S, D

LP(B), S(BA), D(BA)

Plate Style

TGD TGLV

TGB

1-Gang KP Series Plate 1-Gang KP Series Bezel

KP8

X X

X X X X X X

X X X X X X

X X X X X X

X X X X X X

X X

X X X X X X

X X X X X X

X X X X X X

X X

X X X X X X

X X

X X X X X X

KPIMBZ IFP12OW IMF1OW IFP126OW IFP18OW IMF2OW IFP29OW

1-Gang Standard Data Plate 1-Gang iSTATION Plate Frame

Style Line® Data Plate

Duplex Data Plate

2-Gang iSTATION Plate Frame 2-Gang Standard Data Plate

X X

X X X

2-Gang KP Series Plate

KP82

Note: Hubbell Office White plates and devices color match all non-metallic raceway systems.

Physical Properties (When tested in accordance with UL 5A)

Codes/Standards EIA/TIA UL Standard Listings CSA Standard Certified

PlugTrak Specifications Receptacle Rating Wire

569A UL 5A E118895 / E119190 C22.2 no. 62 LR87514

NEMA 5-15R & 5-20R #12 AWG Stranded Copper Thermoplastic

Impact Resistance Crush Resistance Temperature Range Flame Rating Material

5 ft. lbs. 300 lbs. -25.6° to 158° F UL94V-0 UV Stabilized PVC

Receptacle Face

Dimensions in Inches (mm)

www.hubbell.com/wiringdevice-kellems | U-63

Made with FlippingBook - Online Brochure Maker