Traffic Signal Cabinet Bases (HECI-T)
Traffic Signal Cabinet Bases (HECI-T)
Built to Protect.
Page 1 | November 2011
Page 2 | November 2011
TABLE OF CONTENTS
Table of Contents. ..................................................3 Traffic Signal Cabinet Bases............................... 4-5 Box Pads..................................................................6 Flat Pads..................................................................7 Transportation Industry Products.................... 8-12
DRAWINGS...................................................... 14-39
NEMA TYPE M CABINET BASE …….....................14 NEMA TYPE P44 CABINET BASE …..... 17-19, 21-23 332 CABINET BASE……………….........…..16-18, 20 332D CABINET BASE……………............. ……19, 23 332E CABINET BASE……………......... ……16-18, 20 332L CABINET BASE……………......... ……16-18, 20 333 CABINET BASE………………....…..17-19, 21-23 333L CABINET BASE……………....……17-19, 21-23 333JP CABINET BASE………….....…….17-19, 21-23 334 CABINET BASE……………......... ……..16-18, 20 334L CABINET BASE……………......... ……16-18, 20 336 CABINET BASE…………….................... ……..15 336L CABINET BASE…………….................... ……15 340 ITS CABINET BASE…………......…..17-19, 21-23 341 CABINET BASE…………….......... …….16-18, 20 342 ITS CABINET BASE…………...........…..16-18, 20 346 ITS CABINET BASE……………........................15 24 x 36 Traffic Signal Cabinet Bases. ...................14 25 x 25 Traffic Signal Cabinet Bases. ...................15 24 x 36 Traffic Signal Cabinet Base......................16 40 x 44 Traffic Signal Cabinet Bases. ..................17 40 x 58 Traffic Signal Cabinet Bases. ............. 18-19 40 x 44 Combination Traffic Signal/ Battery Backup Cabinet Base...............................20 27 x 45 Traffic Signal Base with self contained UPS battery storage..............................................21 48 x 54 Traffic Signal Base....................................22 50 9/16 x 80 Traffic Signal Base............................23 46 x 87 Traffic Signal Base....................................24 Work Pad...............................................................25 Median Barrier Enclosure.....................................26 Jersey Style edian Barrier Enclosure....................27
TABLE OF CONTENTS
Installation Instructions.................................. 28-30
Page 3 | November 2011
Traffic Signal Cabinet Bases – Cost-Effective Answers
Efficiency, strength, and resistance have been the hallmarks of Hubbell Traffic Signal Cabi net Bases solutions for more than 40 years. As an industry leader, Hubbell is known for man ufacturing safe and cost-effective solutions for Traffic Signal Cabinet Bases while providing peace of mind for utilities contractors and municipalities across North America. Hubbell’s reduced installation costs and unparalleled quality add up to a safer, more cost-effective and durable Traffic Signal Cabinet Bases solutions. Hubbell is the premier American manufacturer of box pads, ground sleeves, flat pads, enclo sures, and foundations. Hubbell’s traffic signal cabinet bases offer a number of advantages over competitors’ products made of conventional materials. Assuring Excellence – The Quality Process For Hubbell, quality assurance is more than just a feel-good term; it’s a sophisticated, process-inspired approach driven by our dedicated professionals. Our goal: to assure that excellence is inherent in every aspect of the manufacturing process. Our quality control processes are among the most advanced in the industry, with all materials strictly adhering to established industry standards.
TRAFFIC SIGNAL CABINET BASES
Page 4 | November 2011
Features – A Distinct Advantage
TRAFFIC SIGNAL CABINET BASES
With stronger, more cost-efficient equipment, Hubbell Traffic Signal Cabinet Bases offer a num ber of advantages over competitors’ products made of conventional materials. Hubbell materials are stronger, weigh less, more corrosion resistant, better able to withstand freeze thaw cycles, and easier to handle. These are the hallmarks of Hubbell’s Traffic Signal Cabinet Bases. • Lightweight – 1/10 to 1/3 the weight of concrete • High Strength – Compressive, flexural and tensile strengths three to five times that of tradi tional concrete • Cost-Effective – Easy to handle, no special equipment required to install. Outperforms conven tional materials for longer service and lower life cycle costs • Stable Under Freeze/Thaw Conditions • Impact Resistant – Tested per ASTM D-2444 • Low in Water Absorption – Less than 1% per ASTM D-570 • Chemical, Corrosion, and UV Resistant – Resistant to alkalines, acids, weathering, and other forms of deterioration • Nonflammable – Will not support combustion • Nonconductive – No grounding required
One Stop – Product Breadth
By utilizing an array of designs, materials, and sizes, Hubbell has developed a comprehensive product offering tailored to your current and future needs. We can provide traffic signal bases for virtually any piece of equipment.
Page 5 | November 2011
Box Pads & Foundations – Advanced Efficiency
Hubbell box pads and foundations are easy to use, cost effective, and time efficient. As the premier American manufacturer of box pads, ground sleeves, flat pads, enclosures and foundations, Hubbell can meet your needs..
Box Pads – Accommodating. Convenient. Strong. Hubbell box pads are designed to work with an array of traffic signal cabinets and feature a variety of benefits.
Many Benefits: · Hubbell’s box pad elevates the traffic signal cabinet to a more comfortable work height. · The large, open interior of a Hubbell box pad provides extra work space. · Hubbell provides models specifically designed to facilitate the installation of cabinets with battery backup. · Installation of the entire unit can be completed in a single day without the need for special equipment. · Eliminates forming and pouring of concrete.
BOX PADS & FOUNDATIONS
Page 6 | November 2011
Flat Pads – Power Under Pressure
The unique strengths of polymer concrete ensure that Hubbell-produced Flat Pads can support equipment weight without cracking or breaking.
Many Benefits: · Resistant – Unlike precast and poured-in-place concrete pads, Hubbell Flat Pads are stable under loading during cold temperatures, aren’t susceptible to damage caused by freeze and thaw cycles, and are resistant to corrosion caused by weathering, road chemi cals, and equipment lubricants. Hubbell pads also resist UV rays, chemicals, and water absorption.
· Efficient – The durability of polymer concrete means lower maintenance and life cycle costs.
FLAT PADS
Page 7 | November 2011
To Select the Traffic Signal Cabinet Base You Need for Your Application: 1..... Determine Type of Cabinet
Traffic Signal Cabinet Base Selection Guide
2..... Determine Work Pad Requirements 3......Determine Performance Requirements 4......Determine Installation Requirements
Using This Selection Guide
Follow the steps outlined in this guide to select the appropriate traffic signal cabinet base for your application. For more information or for answers to any questions you might have, call your local HUBBELL ® representative. Detailed product drawings are included in this section and also can be accessed from our website:
PRODUCTS
TRANSPORTATION INDUSTRY
1
Determine Type of Cabinet HUBBELL ® offers a variety of traffic signal cabinet bases that work with every NEMA and 170E cabinet manufactured today. The footprint of the cabinet will determine which base to install. Please see the Traffic Signal Cabinet Base Cross Reference Guide on pages 81 - 82 to choose the proper base for your application. If your cabinet is not listed, please feel free to contact your local HUBBELL ® representative. Throat sizes and insert locations can be tailored to meet your requirements.
Determine Work Pad Requirements Hubbell offers work pads to accompany all of the traffic signal cabinet bases. If the cabinet is to be installed on a surface other than a sidewalk, a work pad may be necessary to provide stable, dry footing. An alternative option to using a flat work pad in front of the traffic signal cabinet base is to use an enclosure instead. An enclosure serves as a splice box and the work pad also provides a skid resistant walking surface. Hubbell offers a wide variety of enclosure sizes and depths to choose from. Your local HUBBELL ® representative is available to assist you in selecting the appropriate enclosure and options to suit your application. 2
Many Departments of Transportation choose HUBBELL ® traffic signal cabinet bases when they have projects requiring new and retrofit installations of traffic control cabinets. HUBBELL ® traffic signal cabinet bases are less expensive than concrete to install, can be quickly installed by employees, can be relocated and can reduce potential injury and/or liability if struck by a vehicle. In this particular application, the DOT had previously poured concrete in place at an approximate cost of $1,000 for each traffic signal foundation. The installation process using concrete could take up to a week or more depending on weather and involved having to schedule around other work crews. The cost of the QUAZITE ® base was $500 (1/2 the cost of the alternative method) and installation time was reduced to one-half day.
Information shown in catalog is a partial listing.If pad or throat size desired is not listed, contact HUBBELL field sales office.
Page 8 | November 2011
To Select the Traffic Signal Cabinet Base You Need for Your Application: 1..... Determine Type of Cabinet
2......Determine Work Pad Requirements 3......Determine Performance Requirements 4......Determine Installation Requirements
Traffic Signal Cabinet Base Cross Reference Guide McCAIN Cabinets
McCAIN Cabinets Type Bolt Pattern Hubbell® Part No. PB27452139502 PB27452139501 PB27452139500 PL54483620B4T PH50804021B6T 333JP 40 3/4 x 18 1/2 PB40440608B15
McCAIN Cabinets Type Bolt Pattern Hubbell® Part No.
Type Bolt Pattern Hubbell® Part No.
303/308 varies
PB25251212B24 PB25251212B24 PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T PB40582230500 PH50804021B6T PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T
PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB27452139502 PB27452139501 PB27452139500 PL54483620B4T PH50804021B6T PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T PB25251212B24
330 332
varies 25 x 15
PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB27452139502 PB27452139501 PB27452139500 PL54483620B4T PH50804021B6T PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T
342 ITS 25 x 15
332D 39 1/4 x 25
332E 25 x 15
334
25 x 15
346 ITS 15 x 6 NEMA M TS1
26 1/2 x 13 1/2 PB24360612B18
NEMA M TS2 Type 2 Standard
26 1/2 x 13 1/2 PB24360612B18
NEMA P44 TS1
40 3/4 x 18 3/4 PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB27452139502 PB27452139501 PB27452139500 PL54483620B4T PH50804021B6T 40 3/4 x 18 3/4 PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB27452139502 PB27452139501 PB27452139500 PL54483620B4T PH50804021B6T
332L 25 x 15
334L 25 x 15
NEMA P44 TS2
333 40 3/4 x 18 1/2 PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB27452139502 PB27452139501 PB27452139500 PL54483620B4T PH50804021B6T 333L 40 3/4 x 18 1/2 PB40440608B15
336 13 1/2 CL PB25251212B24 336L 13 1/2 CL PB25251212B24 337 varies PB25251212B24 341 25 x 15 PB24361117B18 PH46881020B6T PH50804021B6T PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500 PB40441323A24 PH46881020B6T 340 ITS 40 1/2 x 18 1/2 PB40440608B15
If your cabinet is not listed here, please contact your local HUBBELL ® representative for additional sizes and insert configurations. Information shown in catalog is a partial listing.If pad or throat size desired is not listed, contact HUBBELL field sales office.
PB40440608B24 PB40440928B24 PB40441218B24 PB40580616B24 PB40581024B24 PB40581224B24 PB40582230500
PB40440608B24 PB40440928B24 PB40441218B24
Page 9 | November 2011
To Select the Traffic Signal Cabinet Base You Need for Your Application: 1..... Determine Type of Cabinet
2......Determine Work Pad Requirements 3......Determine Performance Requirements 4......Determine Installation Requirements
Traffic Signal Cabinet Base Cross Reference Guide
Erpel (EDC)
Traffic Signal Cabinet Base Cross Reference Guide
NEMA/
Hubbell®
Cabinet Part No. 170 Ref. Part No. Double DBL363213 — PB40440608B15 Door PB40440608B24 DBL483615 — PB40440608B15 PB40440608B24 DBL604415 — PB40580616B24 DBL724818 — PB40580616B24 DBL724824 — PB40580616B24 DD604830 — PB40580616B24 Flush FD503119 — PB40440608B15 Door PB40440608B24 FD553826 — PB40440608B15 PB40440608B24 FD773826 — PB40440608B15 PB40440608B24 FD554426 — PB40580616B24 FD774426 — PB40580616B24 Front & FDR363624 — PB40440608B15 Rear PB40440608B24 Door FDR443624 — PB40440608B15 PB40440608B24 FDR773826 — PB40440608B15 PB40440608B24 FDR774426 — PB40580616B24 Quad LQD774826 — PB40580616B24 Door LQD484836 — PB40580616B24 LQD605036 — PB40580616B24 LQD605636 — PB40580616B24 Pedestal TPE401608 — PB24360612B18 EnclosureTPE401615 — PB25251212B24 Large LSD301815 2B PB24360612B18 Single LSD362015 3B PB24360612B18 Door LSD412516 G PB24360612B18 LSD512516 K PB24360612B18 LSD503017 M PB24360612B18 LSD583017 MSX PB24360612B18 LSD763017 MXX PB24360612B18 LSD503617 M36 PB40440608B15 PB40440608B24 LSD723617 — PB40440608B15 PB40440608B24 LSD363624 — PB40440608B15 PB40440608B24 LSD443624 — PB40440608B15 PB40440608B24 LSD553826 P-38 PB40580616B24 LSD773826 R-38 PB40580616B24 LSD554426 P-44, R-44 PB40440608B15 PB40440608B24 LSD774426 R-44
NEMA Cabinets
Type
Bolt Pattern
PB24360612B18 PB40440608B15 PB40440608B24 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 Hubbell® Part. No. PB24360612B18 PB40440608B15 PB40440608B24 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 PB25251212B24 PB25251212B24 Hubbell® Part. No.
M P
CL x 12
40 3/4” x 18 1/2”
PRODUCTS
P-38
34 1/2” x 18 1/2”
P-44
40 3/4” x 18 1/2”
TRANSPORTATION INDUSTRY
R
40 3/4” x 18 1/2”
R-38
34 1/2” x 18 1/2”
R-44
40 3/4” x 18 1/2”
170 Controllers
Type
17” x 12 1/2” Bolt Pattern
330 332
25” x 15”
334
25” x 15”
336
15” x 6”
336 (A & S) 15” x 6”
Safetran #170
Type
Bolt Pattern
PB25251212B24 Hubbell® Part. No.
334C 15” x 6”
Signal Control
Type
Bolt Pattern
PB25251212B24 Hubbell® Part. No.
336/332 15” x 6”
PB40440608B15 PB40440608B24 PB25251212B24
Southern Cabinets
Rack ERM392421 336
Mount
ERM462421 336 PB25251212B24 ERM463027 — PB40440608B15 PB40440608B24 ERM553027 — PB40440608B15 PB40440608B24 ERM672430 332 PB40440608B15 PB40440608B24 PB40580616B24 ERM672438 — PB40440608B15 PB40440608B24 332
Type
Bolt Pattern 26 1/2” x 13 1/2”
Hubbell® Part. No. PB24360612B18 PB40580616B24 PB40440608B15 PB40440608B24 PB40580616B24 PB40580616B24 PB25251212B24 PB40580616B24 PB25251212B24 PB25251212B24
IV
V
30” x 18”
V-44
40 3/4” x 18 1/2”
VI
30” x 18” 25” x 15” 25” x 15”
332
336S 15” x 15”
336
15” x 15”
If your cabinet is not listed here, please contact your local HUBBELL ® representative for additional sizes and insert configurations. Information shown in catalog is a partial listing. If pad or throat size desired is not listed, contact HUBBELL field sales office.
Page 10 | November 2011
To Select the Traffic Signal Cabinet Base You Need for Your Application: 1......Determine Type of Cabinet 2......Determine Work Pad Requirements 3..... Determine Performance Requirements 4......Determine Installation Requirements
TRANSPORTATION INDUSTRY
Traffic Signal Cabinet Base Selection Guide
PRODUCTS
3
Determine Performance Requirements HUBBELL ® traffic signal cabinet bases are constructed of strong polymer concrete and reinforced with a heavy-weave fiberglass. Unlike concrete bases, polymer concrete bases are frangible and will break away when subjected to severe impact. This feature helps reduce the risk of serious injury or fatalities resulting from these incidents. HUBBELL ® polymer concrete traffic signal cabinet bases also resist UV rays, chemicals and water absorption. Concrete bases are susceptible to damage caused by freeze/thaw cycles. Thermoplastic fiberglass bases can become brittle and eventually crack when exposed to the weather. The durability that QUAZITE ® provides means lower maintenance and life cycle costs.
Traffic Signal Cabinet Base Performance HUBBELL ® Precast Polymer Precast
Poured-in-Place Thermoplastic /
Aluminum and
Performance Criteria
Concrete Bases Concrete Bases Concrete Bases Fiberglass Bases
Steel Bases
Stable under loading during high temperatures (won’t flex or warp)
X
X
X
X
Stable under loading during cold temperatures (won’t crack)
X
X
Not susceptible to damage caused by freeze/thaw cycles
X
X
X
Resistant to corrosion caused by weathering, road chemicals
X
X
and equipment lubricants
Provides long-term durability (fatigue or creep resistant)
X
X
X
X
Frangible base will break away when cabinet is struck by a vehicle
X
X
Information shown in catalog is a partial listing. If pad or throat size desired is not listed, contact HUBBELL field sales office.
Page 11 | November 2011
To Select the Traffic Signal Cabinet Base You Need for Your Application: 1......Determine Type of Cabinet
2......Determine Work Pad Requirements 3......Determine Performance Requirements 4..... Determine Installation Requirements
Traffic Signal Cabinet Base Selection Guide
4
Installing HUBBELL ® traffic signal cabinet bases is easy and cost effective because it requires no special equipment to set the base. A backhoe is all that is necessary to lift the base in place. HUBBELL ® traffic signal cabinet bases also save time during installation. Unlike poured-in-place bases that take days to form, pour, set and remove the forms, HUBBELL ® traffic signal cabinet bases can be installed quickly, allowing the cabinet and equipment installation to begin immediately after setting the base. Determine Installation Requirements
PRODUCTS
TRANSPORTATION INDUSTRY
Traffic Signal Cabinet Base Installation HUBBELL ® Precast Polymer Precast
Poured-in-Place Thermoplastic /
Aluminum and
Installation Criteria
Concrete Bases Concrete Bases Concrete Bases Fiberglass Bases
Steel Bases
Easily installed in areas with limited accessibility
X
X
X
Minimal planning and scheduling of crews required for installation
X
X
X
No special equipment (such as a boom truck or crane) needed for installation
X
X
X
Easily installed by no more than two crew members (light weight)
X
X
X
Cabinet and base can be easily installed in the same day
X
X
X
X
Pad Numbering System
Weight
Style
Size Throat Size
Item
Depth Surface
P
B
4846 0817
A
3 T
8” x 17”
B - Box pad H - Electrical equipment pad
S - Smooth T - Skid resistant
3” thick (Indicates surface thickness if flat pad; indicates depth if box pad.)
48” x 46”
A - 3/8-16 UNC inserts B - 1/2-13 UNC inserts C - 5/8-11 UNC inserts E - 5/8 thru hole F - Struts w/ 3/8” inserts G - Struts w/ 1/2” inserts H - Struts w/ 5/8” inserts
L - Lightweight mix P - Standard mix
J - Split electrical equipment pad K - Split telecommunications equip ment pad L - Telecommunications equipment pad
Dimensions run parallel to each other.
Information shown in catalog is a partial listing. If pad or throat size desired is not listed, contact HUBBELL field sales office.
Page 12 | November 2011
DRAWINGS & TABLES
DRAWINGS
Page 13 | November 2011
Specifications / Data
24 x 36Traffic Signal Cabinet Base for NEMAType“M”Cabinets
NEMATYPE M MOUNTING PATTERN: 25”X 12”
DRAWINGS
Traffic Signal Cabinet Base for NEMA Type M Cabinet – 24” x 36” TOP DIM’S. (in.) THROAT SIZE (in.) DEPTH (in.) WEIGHT (lbs.) PALLET QTY.
PART NO.
24 1/8 X 36 1/8
18
6X12
159
3
PB24360612B18
Page 14 | November 2011
Specifications / Data 25 x25Traffic Signal Cabinet Base for 336, 336L & 346 ITS Cabinets
336, 336L, 346 ITS MOUNTING PATTERN: 6”x 6”x 15”
DRAWINGS
Traffic Signal Cabinet Base for 336, 336L 346 ITS Cabinets – 25” x 25” TOP DIM’S. (in.) THROAT SIZE (in.) DEPTH (in.) WEIGHT (lbs.) PALLET QTY. PART NO. 25 X 25 12 X 12 24 144 2 PB25251212B24
Page 15 | November 2011
Specifications / Data
24x36Traffic Signal Cabinet Bases
for 332, 332E, 332L, 334, 334L, 341 & 342 ITS Cabinets
332, 332E, 332L, 334, 334L, 341 & 342 ITS MOUNTING PATTERN: 25”X 15”
DRAWINGS
Traffic Signal Cabinet Base for Type 332, 332E, 332L, 334, 334L, 341 & 342 ITS Cabinets -24 x 36 TOP DIM’S. (in.) THROAT SIZE (in.) C (in.) WEIGHT (lbs.) PALLET QTY. PART NO. 24 1/8 X 36 1/8 11x17 18 176 3 PB24361117B18
Page 16 | November 2011
Specifications / Data
40 x 44Traffic Signal Cabinet Bases
for 332, 332E, 332L, 333, 333L, 333JP, 334, 334L 340 ITS, 341, 342 ITS & NEMA P44 Cabinets
332, 332E, 332L, 333, 333L, 333JP, 334 334L 340ITS, 341, 342 ITS & NEMA P44 MOUNTING PATTERNS: 40 1/2”x 18 1/2” 25”X 15”
DRAWINGS
Traffic Signal Cabinet Base for 332, 332E, 332L, 333, 333L, 333JP, 334, 334L, 340 ITS, 341, 342 ITS & NEMA P44 Cabinets – 40 x 44
TOP DIM’S. (in.)
A x B (in.) 6 X 8 6 X 8 9 X 28
C (in.)
WEIGHT (lbs.)
PALLET QTY.
PART NO.
40 X 44 40 X 44 40 X 44 40 X 44
15 24 24 24
281 378 385 366
3 3 3 3
PB40440608B15 PB40440608B24 PB40440928B24 PB40441218B24
12 X 18
Page 17 | November 2011
Specifications / Data 332, 332E, 332L, 333, 333L, 333JP, 334, 334L, 340 ITS, 341, 342 ITS & NEMA P44 MOUNTING PATTERNS:
40 x 58Traffic Signal Cabinet Bases
for 332, 332E, 332L, 333, 333L, 333JP, 334, 334L, 340ITS, 341, 342 ITS & NEMA P44 Cabinets
40 1/2” x 18 1/2” 34 1/2“ x 18 1/2“
30”x 18” 25”X 15”
DRAWINGS
Traffic Signal Cabinet Base for 332, 332E, 332L, 333, 333L, 333JP, 334, 334L, 340 ITS, 341, 342 ITS & NEMA P44 Cabinets – 40 x 58
TOP DIM’S. (in.)
A x B (in.) 6 X 16
C (in.)
WEIGHT (lbs.)
PALLET QTY.
PART NO.
40 X 58 40 X 58 40 X 58
24 24 24
450 440 435
3 3 3
PB40580616B24 PB40581024B24 PB40581224B24
10 X 24 12 X 24
Page 18 | November 2011
Specifications / Data
40 x 58Traffic Signal Cabinet Base
332D, 333, 333L, 333JP, 340 ITS, NEMA P44 & NEMA P44 MOUNTING PATTERNS: 40 7/8” x 18 1/2” 39 1/2” X 25” for 332D, 333, 333L, 333JP, 340 ITS, NEMA P44 Cabinets
DRAWINGS
Traffic Signal Cabinet Base for 332D, 333, 333L, 333JP, 340 ITS, NEMA P44 Cabinets – 40 x 58
TOP DIM’S. (in.)
THROAT SIZE (in.)
C (in.)
WEIGHT (lbs.)
PALLET QTY.
PART NO.
40 X 58
24
22x30
355
3
PB40582230500
Page 19 | November 2011
Specifications / Data 40 x 44 CombinationTraffic Signal/Battery Backup Cabinet Base
for 332, 332E, 332L, 334, 334L, 341 & 342 ITS Cabinets
332, 332E, 332L, 334, 334L, 341 & 342 ITS MOUNTING PATTERN: 25”X 15”
DRAWINGS
For Traffic Signal Controller and Battery Backup System
Traffic Signal/Battery Backup Cabinet Base for 332, 332E, 332L, 334, 334L, 341 & 342 ITS Cablnets – 40 x 44
TOP DIM’S. (in.)
DEPTH (in.)
WEIGHT (lbs.)
PALLET QTY.
PART NO.
40 X 44
24
389
3
PB40441323A24
Page 20 | November 2011
Specifications / Data 27 x 45Traffic Signal Controller Base with Self Contained UPS Battery Storage
333, 333L, 333JP, 340 ITS & NEMA P44 MOUNTING PATTERNS: 40 3/4”x 18 1/2” for 333, 333L, 333JP, 340 ITS & NEMA P44 Cabinets
DRAWINGS
Traffic Signal Controller Base for 333, 333L, 333JP, 340 ITS & NEMA P44 Cabinets – 27 x 45
TOP DIM’S. (in.)
DEPTH (in.)
WEIGHT (lbs.)
PALLET QTY.
ACCESSORIES
PART NO.
27 X 45 27 X 45
24 24
232 232
2 2
Cable Rack Strain Relief Supports for Conductors
PB27452139502 PB27452139500
Cable Rack & Full Strain Relief Supports for Conductors Cable Rack & Full Strain Relief Supports for Conducotors Battery Support Grates (4)
27 X 45
24
244
2
PB27452139501
Page 21 | November 2011
Specifications / Data
48x 54Traffic Signal Cabinet Base
for 333, 333L, 333JP, 340 ITS & NEMA P44 Cabinets
333, 333L, 333JP, 340 ITS & NEMA P44 MOUNTING PATTERN: 40 3/4 X 18 1/2
DRAWINGS
Traffic Signal Cabinet Base for 333, 333L, 333JP, 340 ITS & NEMA P44 Cabinets – 48 x 54
A. (in.)
B (in.)
C (in.)
D (in.)
E (in.)
F (in.) 5 5/8
G (in.) 8 5/8
INSERTS (in.)
WEIGHT (lbs.) PALLET QTY.
PART NO.
48
4
1/2-13 (4X)
54 20 11/16 36 11/16
203
5
PL54483620B4T
Page 22 | November 2011
Specifications / Data
50 9/16 x 80 Traffic Signal Cabinet Base
332D, 333, 333L, 333JP, 340 ITS & NEMA P44 MOUNTING PATTERNS: 40 13/16” x 18 1/2” 39 1/2” x 25 X 15” for 332D, 333, 333L, 333JP, 340 ITS & NEMA P44 Cabinets
DRAWINGS
Traffic Signal Cabinet Base 332D, 333, 333L, 333JP, 340 ITS, NEMA P44 Cabinets – 50 9/16 x 80
A. (in.)
B (in.)
C (in.)
D (in.)
E (in.)
INSERTS (in.)
WEIGHT (lbs.) PALLET QTY.
PART NO.
50 9/16
40 5/8 22 1/8 3 1/4 1/2-13 (8X)
80
443
5
PH50804021B6T
Page 23 | November 2011
Specifications / Data
46 x 87 1/2 Traffic Signal Cabinet Base
for 332, 332E, 332L, 334, 334L, 341 & 342 ITS Cabinets
332, 332E, 332L, 334, 334L, 341 & 342 ITS MOUNTING PATTERN: 25”X 15”
DRAWINGS
Traffic Signal Cabinet Base for 332, 332E, 332L, 334, 334L, 341 & 342 ITS Cabinets – 46 x 87 1/2
A. (in.)
B (in.)
C (in.)
D (in.)
E (in.)
INSERTS (in.)
WEIGHT (lbs.) PALLET QTY.
PART NO.
46
11 1/8 21 1/8 3 1/4 1/2-13 (4X)
88
462
5
PH46881020B6T
Page 24 | November 2011
Specifications / Data
Work Pad
DRAWINGS
Work Pads
A X B (in.)
WEIGHT (lbs.)
PALLET QTY
PART NO.
24 X 25 24 X 36 24 X 58
70 95
5 5 5
PH242500002T PH243600002T PH245800002T
160
Page 25 | November 2011
Specifications / Data
5 x 16Median Barrier Enclosure
Covers
DESCRIPTION
TIER DESIGN / TEST LOAD #
WEIGHT #
PALLET QTY
PART NO.
DRAWINGS
W/ 4 Bolts W/ 2 Bolts
8 8
8,000 / 12,000 8,000 / 12,000
6 6
36 36
PC0516CA00 PC0516C500
Boxes
DESCRIPTION
DEPTH
TIER DESIGN / TEST LOAD # WEIGHT # PALLET QTY PART NO.
Closed Bottom Closed Bottom
7 1/2” 7 1/2”
15 15
15,000/22,500 15,000/22,500
25 25
36 36
PC0516BA12 PC0516B500
Page 26 | November 2011
Specifications / Data
10 x 12 Jersey Style Median Barrier Enclosure
DRAWINGS
Covers
DESCRIPTION
TIER DESIGN / TEST LOAD #
WEIGHT #
PALLET QTY
PART NO.
W/ 4 Bolts W/ 2 Bolts
8 8
8,000 / 12,000 8,000 / 12,000
8 8
24 24
PC1012CA00 PC1012C500
Boxes
DESCRIPTION
DEPTH
TIER DESIGN / TEST LOAD # WEIGHT # PALLET QTY PART NO.
Solid Bottom Solid Bottom
8” 8”
15 15
15,000/22,500 15,000/22,500
23 23
24 24
PC1012BA15 PC1012B500
Page 27 | November 2011
INSTALLATION INSTRUCTIONS
Page 28 | November 2011
Traffic Signal Cabinet Base Installation
Installation Instructions
1. General 1.01 This section covers the description, installation and use of traffic signal cabinet bases for traffic signal cabinets. 1.02 The foundation base is designed for most cabinets now being used in the field. 2. Description and Use 2.01 The foundation base is constructed of polymer concrete and reinforced by a heavy-weave fiberglass mat. 2.02 The types and sizes of the bases vary depending on the size of the cabinet to be installed. 2.03 Inserts (1/2” anchors) are molded into the base and must align with the cabinet footprint. 2.04 Base is resistant to most chemicals. 3. Installation 3.01 The following installation procedure is the same for all sizes of foundation pads. 3.02 Determine cable/conduit entry position. 3.03 Excavate to the proper depth for traffic cabinet signal base. (The base should extend no more than 50% above grade level.) 3.04 Excavate the site to the proper depth as determined by the final grade. The work pad may be installed directly on undisturbed soil. (If the soil compaction is substandard, or if you wish to provide drainage, you need to lower the excavation 4” to 6” to accommodate pea gravel.) 3.05 Install conduit, 90 o bends, to extend at least 2” above final grade of the base. 3.06 Compact the soil or pea gravel base. 3.07 Install the traffic signal cabinet base. When lowering the base in place,
INSTALLATION
be sure the conduit is straight in line with the opening on the top surface of the base. After setting the base, check for alignment and plumb.
3.08 Backfill evenly around the base to maintain alignment and plumb. Tamp backfill after each 4” fill. Fill 1” to 2” above grade and tamp to grade. 3.09 Set the cabinet.
Page 29 | November 2011
Box Pads and Ground Sleeves Installation
Hubbell Box Pads and Ground Sleeves can be easily installed by following these simple guidelines:
1. Determine the cable or conduit entry position and then excavate a hole for the base.
2. Make the hole 1 to 2 feet longer and wider than the base, and approximately 8 inches deeper.
3. Put eyebolts into lifting inserts on top of the base. (Four bolts are shipped with the foundation base.) Attach lifting chain or straps to the bolts. Once chain or straps are attached, lift and position the base into the hole using a backhoe. Check plan for proper orientation of box pad or ground sleeve. 4. Place gravel in the base to a depth of approximately 6 to 8 inches. Lift base to proper elevation, allow ing gravel to run out under the base. Check the elevation of the base, make the necessary elevation adjust ments with the bucket, and then recheck the elevation. 5. Once the base is set to proper elevation, remove the bolts and place backfill around the box pad using normal utility practices for backfilling. If compaction is required, internal bracing should be used for all manufacturers’ enclosures to prevent deflection and premature failure.
INSTRUCTIONS
Equipment Support Pads Installation
Hubbell Support Pads can be easily installed by following these simple guidelines:
1. Determine the cable or conduit entry position, then dig a recess so the top surface of the pad will be level with the surrounding area.
2. Level the dirt around cable opening, and then level and tamp down dirt in the area to be occupied by the foundation pad. 3. Backfill and tamp in trench area leading to cable opening. Place pad in a prepared, level area with opening in pad (throat) directly over cable entry position. 4. Attach equipment to the foundation pad with bolts, brackets, and/or lugs provided by the equipment manufac turer. Backfill and tamp earth around the pad so it is level with surrounding landscape.
Page 30 | November 2011
Page 31 | November 2011
numbering system key
Hubbell Enclosures 3621 Industrial Park Drive • Lenoir City, Tennessee 37771 Phone: 800.346.3062 or 865.986.9726 • Fax: 865.986.0585 hubbellenclosures@hubbell.com
NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice. ©Copyright 2011 Hubbell Incorporated
Page 32 | November 2011 NEVER COMPROMISE ™ www.hubbellpowersystems.com
NOVEMBER 2011 5M RGS 12/11
Catalog # HECI-T
Made with FlippingBook Online newsletter