CMC Product Master Catalog

Animated publication

Searchby productlineor name,SKUor productfeature Toglebetwen singleand doublepage viewsbasedon yourpreference Downloadindi vidualpagesor pagerangesto shareorsave Adnotes throughoutthe catalogtokep trackof comments, questions,and product options Sendindividual catalogpages directlytomail in-boxesor poston LinkedInwitha singleclick Cropimagesor specificpieces ofinformation toshare, downloador print Viewpage thumbnailsfor fasteraces tospecific productsectors Createawish listwithinthe catalogthat canberevis itedatanytime Usethearows, bokmarksor tableof contentstabto makenaviga tionabreze

ConectorManufacturingCompany 3501SymmesRoad Hamilton,Ohio45015 Phone:513-860-4455|www.cmclugs.com

PICTORIAL INDEX UTILITY PRODUCTS

Submersible Underground Connectors

Waterproof Streetlight Connectors

Rubber Insulated Secondary Connectors

"RESIDENTIAL EEL" Pedestal Connectors

Pedestal Set Screw Connectors

Compression Lugs and Tap Kits

Rubber Covers and Sleeves

Terminal Lugs and Tap Kits

Cable Repair Splice

EPDM Rubber Splice Covers

Pedestal Connectors

Connectors for Direct Burial, Below-Grade Boxes and Network Underground

Lay-In Connectors

Secondary Connectors

Clear Insulated Secondary Connectors

Space-Saver Secondary Connectors

www.cmclugs.com 513-860-4455

PICTORIAL INDEX UTILITY PRODUCTS

Pedestal Connectors Cont.

Splicer Reducer

Streetlight Connectors

Enclosures and Pedestals

Cable Splicing Enclosures for Wind Turbines

Termination Enclosures

Transformer Connectors

Patented

Space-Saver Transformer Connectors

Stud-Mount Transformer Connectors

Compression Connectors

General Purpose Connectors

NEMA Mounted

Transformer Eyebolt Connectors

Heavy-Duty Connectors

2/15

PICTORIAL INDEX UTILITY PRODUCTS

Transformer Connectors Cont.

Transformer Stud Relocation Bar

Stud Mount Connectors

Pad Extensions

Compression Connectors

Copper Connectors

Splice Kits and Connectors

Stacking Lugs

Pin Terminals

Meter and Grounding

Ground Rod Clamps

Grounding Connectors

Vice-Type Connectors

Ground Clamps

Solderless Connectors

Two-Conductor Solderless Connectors

Three-Conductor Solderless Connectors

Single Hole Solderless Connectors

Panel Board Solderless Connectors

Panel Board Lugs

General Purpose

Tee-Tapped Connectors

Insulated Phase Line Connectors

Parallel Clamps

Bronze Distribution Connectors

www.cmclugs.com 513-860-4455

PICTORIAL INDEX UTILITY PRODUCTS

Overhead Products

Pin Terminals

Transformer Eyebolt Connectors

Hot Line Clamps

Parallel Clamps

Insulated Phase Line Connectors

Bird Guards

Accessories

Penta-Head Wrench

Penta-Head Bolt

Enclosure Locks

Co-Ox Joint Compound

Multi-Tap Adapters

Aluminum Reducer

Bolt Assemblies

Hex Wrench

Cable Caps

Pad Extensions

www.cmclugs.com 513-860-4455

PICTORIAL INDEX UTILITY PRODUCTS

Accessories Cont.

PVC Boots

Dura-Boots

Hot Line Clamps

Underground Covers

Bird Guards

www.cmclugs.com 513-860-4455

SUBMERSIBLE SECONDARY CONNECTORS

TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

RUS Approved SURE-SEAL

600V

• User friendly wide-port spacing (50% more room for cable training). • Multiple seals incorporated into caps and rockets. • High quality EPDM rubber. • Clear plated for low-contact resistance. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5. • Supplied with aluminum set-screws. • Includes silicone grease and CO-OX oxide inhibitor. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC® recommends the use of a 9" insulated hex wrench (no tee handles). • A torque wrnch should be used to ensure the proper torque is achieved.

In dex

L

H

SSBC350-4LI

W

Cond. Range

H

W L

Catalog Number

No. of Cond.

AWG

Dimensions - Inches

MM2

Dimensions - (mm)

350-12

2.75

4.21

4.02

SSBC350-3LI

3

185-4

69.85 106.93 102.11

350-12

2.75

4.21

5.52

SSBC350-4LI

4

185-4

69.85 106.93 140.21

350-12

2.75

4.21

7.02

SSBC350-5LI

5

185-4

69.85 106.93 178.31

350-12

2.75

4.21

8.52

SSBC350-6LI

6

185-4

69.85 106.93 216.41

350-12

2.75

4.21

11.52

SSBC350-8LI

8

185-4

69.85 106.93 292.61

Note: For omission of CO-OX oxide inhibitor delete suffix -"I". For orange screw plugs add suffix -"V".

www.cmclugs.com 513-860-4455

SUBMERSIBLE SECONDARY CONNECTORS

DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Clear plated for low-contact resistance • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Under ground Committee Guide 2.5. • Supplied with aluminum set-screws. • Includes silicone grease and CO-OX oxide inhibitor. TYPE SSBC-S (Standard Spacing) Rubber Insulated Secondary Connectors

RUS Approved 600V SURE-SEAL

• Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC® recommends the use of a 9" insulated hex wrench (no tee handles). • A torque wrench should be used to ensure the proper torque is achieved.

Cond. Range H

W

L

Catalog Number No. of Cond.

AWG MM2

Dimensions - Inches Dimensions - (mm)

350-12

2.46

4.06

2.32

SSBC350-2SI

2

185-4

62.48 103.13 58.93

350-12

2.46

4.06

3.51

SSBC350-3SI

3

185-4

62.48 103.13 89.15

L

350-12

2.46

4.06

4.72

W

SSBC350-4SI

4

185-4

62.48 103.13 119.88

350-12

2.46

4.06

5.93

SSBC350-5SI

5

185-4

62.48 103.13 150.62

350-12

2.46

4.06

7.14

SSBC350-6SI

6

H

185-4

62.48 103.13 181.35

500-12

2.83

4.58

4.25

SSBC500-3SI

3

240-4

79.5 116.33 109.95

500-12

2.83

4.58

5.63 143

SSBC500-4SI

4

240-4

79.5 116.33

500-12

2.83

4.58

7.01

SSBC500-5SI

5

240-4

79.5 116.33 178.05

Note: For omission of CO-OX oxide inhibitor delete suffix - "I ". For orange screw plugs add suffix -"V".

500-12

2.83

4.58

8.39

SSBC500-6SI

6

240-4

79.5 116.33 213.11

500-12

2.83

4.58

9.77

SSBC500-7SI

7

240-4

79.5 116.33 248.16

500-12

2.83

4.58

11.15

SSBC500-8SI

8

240-4

79.5 116.33 283.21

500-12

2.83

4.58

12.53

SSBC500-9SI

9

240-4

79.5 116.33 318.26

www.cmclugs.com 513-860-4455

SUBMERSIBLE SECONDARY CONNECTORS

TYPE SSBC/DESS Rubber Insulated Secondary Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Clear plated for low-contact resistance. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5. • Fully tested to ANSI 119.4 for Class ‘A’ connectors. • Includes CO-OX oxide inhibitor. • Supplied with aluminum set-screws. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC ® recommends the use of a 9" insulated hex wrench (no tee handles). • A torque wrench should be used to ensure the proper torque is achieved.

RUS Approved 600V SURE-SEAL

W

L

H

Catalog Number

No. of Cond.

Cond. Range

H

W L

SSBC750-3I

3

750-2

3.065

5.42

4.57

SSBC750-4I

4

750-2

3.065

5.42

6.13

SSBC750-5I

5

750-2

3.065

5.42

7.69

SSBC750-6I

6

750-2

3.065

5.42

9.25

SSBC750-7I

7

750-2

3.065

5.42

10.81

SSBC

SSBC750-8I

8

750-2

3.065

5.42

12.37

DESS750-3I

3

750-2

3.065

8.15

4.57

DESS750-4I

4

750-2

3.065

8.15

6.13

DESS750-5I

5

750-2

3.065

8.15

7.69

DESS750-6I

6

750-2

3.065

8.15

9.25

DESS750-7I

7

750-2

3.065

8.15

10.81

DESS750-8I

8

750-2

3.065

8.15

12.31

DESS

Note: For omission of CO-OX oxide inhibitor delete suffix - "I". For orange screw plugs add suffix -"V".

www.cmclugs.com 513-860-4455

OVERHEAD OR SUBMERSIBLE SECONDARY CONNECTORS

RUS Approved 600V SURE-SEAL

TYPE SSBC Rubber Insulated Secondary Connectors • Clear plated for low-contact resistance. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5.

• Fully tested to ANSI C119.4 for Class ‘A’ connectors. • Includes CO-OX oxide inhibitor and silicon grease. • Supplied with aluminum set-screws.

• Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC® recommends the use of a 9" insulated hex wrench (no tee handles). • A torque wrench should be used to ensure the proper torque is achieved.

Catalog Number No. of Cond. Cond. Range

H

W

L

SSBC750-1-1

2

750-2

3.07

8.50

4.57

SSBC750-2-1 SSBC750-3-1 SSBC750-4-1 SSBC750-4-2 SSBC750-6-2

3 4 5 6 8

750-2 750-2 750-2 750-2 750-2

3.07 3.07 3.07 3.07 3.07

8.50 8.50 8.50 8.50 8.50

4.57 6.13 7.69 9.25

10.81

Note: Order using first number (SSBC-750- 4 -2) for outlets needed on one side; And second number (SSBC750-4-2) for outlets needed on opposite side.

SSBC750-4-2

W

L

H

www.cmclugs.com 513-860-4455

SUBMERSIBLE SECONDARY CONNECTORS

TYPE ULS EPDM Rubber Insulated Secondary Connectors (Submersible) DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

RUS Approved 600V SURE-SEAL

• Clear plated for low-contact resistance. • Fully tested to ANSI C119.1 and Western Underground Guide 2.5 for submersible applications. • Fully tested to ANSI C119.4 for Class ‘A’ connectors. • Supplied with aluminum set-screws. • Includes silicone grease and CO-OX oxide inhibitor. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation CMC® recommends the use of a 9" insulated hex wrench (no tee handles). • A torque wrench should be used to ensure the proper torque is achieved.

Catalog Number

Fig. No.

Cond. Range H W L Dimensions - Inches

ULS2-350I

1

350-12

2.48

1.34

8.09

ULS2-500I

1

500-10

2.80

1.60

8.09

*ULS2-350-1I 2

350-12

1.90

1.65

8.50

* Not UL listed

Note: For omission of CO-OX oxide inhibitor delete suffix - "I". For orange screw plugs add suffix -"V".

H

Figure 1

L

W

Figure 2

www.cmclugs.com 513-860-4455

INSULATED WATERPROOF STREETLIGHT CONNECTORS

600V

TYPE DSR

• The DSR-K product is a hinged, single piece clamshell housing, each side filled with pre-cured insulating material and a 6061-T6 aluminum alloy connector. • The housing provides physical protection to the insulating material and provides compression that is essential for the sealing properties. • Simple to use - Install the conductors in the connector, position the connector in the cover and close the cover. • Fully tested to ANSI C119.4 and C119.1 and Western Underground Guide 2.5. • Gel pack, water proof cover is included in kits.

Fig. 1

Catalog Number

Conductor Range

Figure Number

DSR1/0-3K 1/0-14 AL-CU DSR-2K 2-14 AL-CU DSR-2/0K 2/0-14 AL-CU SR 4/0 K 2-4/0 AL-CU

1

Fig. 2

2

3

Fig. 3

To order only the Gel Pack Waterproof Cover - Cat # NBD1/0

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

600V

TYPE BRD Submersible Pedestal Set Screw Connector for Direct

Burial or Below-Grade Boxes DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Patented, one-piece extruded aluminum body. • Dual purpose rubber TLS Torpedo cover furnished on all outlets /field cut at marked steps to accommodate specified conductor size. • High capacity bus provides assurance of reliable performance under adverse conditions. • Set-screws accept 5/16” Allen wrench. • Meets performance requirements of ANSI C119.1, ANSI C119.4 for Class ‘A’ and Western Underground Committee Guide 2.5. • Installation instructions and silicon lubricant included.

The listed wire range is without a street light connection made in the same port. When a street light conductor is installed in the same port with a feeder or service conductor, the maximum size rating listed on this page, is reduced as follows: Material: Body - Extruded aluminum 6061-T6 alloy Hardware - Aluminum round bottom set-screws Insulation - EDPM rubber

- With a #10, the max is 300 Str. - With a #8, the max is 250 Str. - With a #6, the max is 4/0 Str. - With a #4, the max is 3/0 Str.

H W Dimensions - Inches Dimensions- (mm)

Catalog Number

Number of Outlets

Conductor Range

3.67 93 5.86 149 7.71 196 9.61 244

BRD2 350TSXB BRD3 350TSXB BRD4 350TSXB BRD5 350TSXB BRD6 350TSXB BRD8 350TSXB BRD2 500TSXB BRD3 500TSXB BRD4 500TSXB BRD5 500TSXB BRD6 500TSXB BRD8 500TSXB

2

3

4

6.75 171

350-12

5

11.49 292 15.24 387

6

8

PATENTED

3.67 93 5.53 140 7.39 188 9.61 244

2

3

Note: Add suffix “SL” for one Torpedo to have dual outlets to accommodate a street light conductor.

4

6.75 171

500-12

5

11.11 282 14.82 376

6

8

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

600V

TYPE BRDD Submersible Pedestal Set Screw Connector for Direct

Burial or Below-Grade Boxes DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Patented, one-piece extruded aluminum body. • Dual purpose rubber TLS Torpedo cover furnished on all outlets /field cut at marked steps to accommodate specified conductor size. • High capacity bus provides assurance of reliable performance under adverse conditions. • Set-screws accept 5/16” Allen wrench. • Meets performance requirements of ANSI C119.1, ANSI C119.4 for Class ‘A’ and Western Underground Committee Guide 2.5. • Installation instructions and silicon lubricant included.

The listed wire range is without a street light connection made in the same port. When a street light conductor is installed in the same port with a feeder or service conductor, the maximum size rating listed on this page, is reduced as follows: Material: Body - Extruded aluminum 6061-T6 alloy Hardware - Aluminum round bottom set-screws Insulation - EDPM rubber

- With a #10, the max is 300 Str. - With a #8, the max is 250 Str. - With a #6, the max is 4/0 Str. - With a #4, the max is 3/0 Str.

H W Dimensions - Inches Dimensions- (mm)

No. of Outlets

Conductor Range

Catalog Number

W

BRDD2-350TSXB 2

3.35

5.20

BRDD3-350TSXB 3

H

BRDD4-350TSXB 4

7.06

350-12 6.75 171

8.92

BRDD5-350TSXB 5

BRDD6-350TSXB 6

10.78

14.50

BRDD8-350TSXB 8

BRDD2-500TSXB 2

3.35

5.20

BRDD3-500TSXB 3

BRDD4-500TSXB 4

7.06

500-12 6.75 171

8.92

BRDD5-500TSXB 5

BRDD6-500TSXB 6

10.78

14.50

BRDD8-500TSXB 8

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

600V

TYPE UC Submersible "RESIDENTIAL EEL" Pedestal Connector used with LA and LA2 Compression Lugs for Direct Burial or Below-Grade Boxes. DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

• Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5. • Terminal pads are supplied assembled with 3/8” diameter hex head cap screws and captive Belleville washer. • Pads include interlocking features with terminal lugs to prevent twisting. Allows field attachments of lugs to be made without removing hardware assemblies.

Casting: Aluminum Hardware: Plated steel cap screws and washers Insulation: PVC Material:

356 Amps and 4/0 AWG Type LAAluminum 12 Str. – 4/0 Str.

572 Amps and 500 kcmil

Type LA2 Aluminum lug 4 Str. – 500 Str. Type LCL copper lug 1/0 Str. -500 Str.

TS Torpedo Sleeve

TL Torpedo Sleeve

Note: Optional set-screw type street light taps for conductor sizes from 12 Sol. – 4 Str. can be provided either on the top of the bus or at one end. To specify top mounting, add suffix “SL” to the listed catalog number or add “SL1” for end mounting. Rubber cover, which doubles as an insulating sleeve, is supplied. Lugs and Torpedo sleeves must be ordered separately. Specific accessory selections can be established, based upon the information on these pages.

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

TYPE UC Submersible "RESIDENTIAL EEL" Pedestal Connector used with LA and LA2 Compression Lugs for Direct Burial or Below-Grade Boxes DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Terminal pads are supplied assembled with 3/8” diameter hex head cap screws and captive Belleville washer. • Pads include interlocking feature with terminal lugs to prevent twisting. Allows field attachments of lugs to be made without removing hardware assemblies. • Meet the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5. Add 225 to Sealant Height Example of “SL” W 600V

Material: Body - Casting - Aluminum

No. of Terminal

Dimensions - Inches (mm)

Approx. Wt. 100 LBS. (KG)

Hardware - Plated steel cap screws and washers Insulation - PVC

Catalog Number

Total Number

1-Bolt Term.

2-Bolt Term.

H

W Sealed Height

UC30 3

3

0 3.38 (86) 5.31 (134) 7.13 (191) 60 (27)

UC31 3

2

1 4.31 (109) 5.69 (144) 9.38 (238) 82 (37)

UC33 3

0

3 4.31 (109) 6.06 (154) 9.38 (238) 128 (58)

UC40 4

4

0 3.38 (86) 7.19 (183) 7.13 (191) 78 (35)

UC41 4

3

1 4.31 (109) 7.69 (195) 9.38 (238) 100 (45)

UC30

UC42 4

2

2 4.31 (109) 7.94 (202) 9.38 (238) 123 (56)

UC44 4

0

4 4.31 (109) 8.19 (208) 9.38 (238) 155 (70)

UC50 5 UC51 5 UC52 5

5 4 3

0 3.38 (86) 9.06 (230) 7.13 (191) 98 (44) 1 4.31 (109) 9.06 (230) 9.38 (238) 121 (55) 2 4.31 (109) 9.19 (249) 9.38 (238) 142 (64)

UC31

UC55 5

0

5 4.31 (109) 10.31 (262) 9.38 (238) 198 (90)

UC60 6

6

0 3.31 (86) 10.31 (278) 7.13 (191) 121 (55)

UC61 6 UC62 6 UC66 6

5 4 0

1 4.38 (109) 11.44 (290) 9.38 (238) 144 (65) 2 4.31 (109) 11.69 (297) 9.38 (238) 167 (76) 6 4.31 (109) 12.44 (316) 9.38 (238) 233 (106)

UC81 8

7

1 4.31 (109) 15.19 (386) 9.38 (238) 188 (85)

UC33

UC88 8

0

8 4.31 (109) 16.69 (424) 9.38 (238) 342 (155)

Note: Optional set-screw type street light taps for conductor sizes from 12 Sol. - 4 Str. can be provided either on the top of the bus or at one end. To specify top mounting, add suffix “SL” to listed catalog number or add “SL1” for end mounting. Rubber cover which doubles as an insulating sleeve is supplied. Lugs and Torpedo sleeves must be ordered separately. Specific accessory selections can be established based upon the information on these pages.

www.cmclugs.com 513-860-4455

TYPE LA Aluminum Terminal Lugs and Tap Kits for use on UC Connectors UNDERGROUND COMPRESSION CONNECTORS 600V

DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

Material: Terminal - Aluminum

• Offered as individual terminal lugs or in kit form, complete with a Torpedo sleeve. Kits are offered in two types: One type consists of the lug and uncut torpedo cover The other consists of the lug and a Torpedo sleeve factory cut at the appropriate conductor step to match the wire size of a particular lug. • Hook-on terminal lugs have side tabs to mate with locking recesses provided in the corresponding pads of “RESIDENTIAL EEL” series types UC. • Common die terminal lugs are pre-filled with electrical joint compound and capped with color coded plugs. Field instructions and lubricant are supplied with kits. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5.

Fig.3

Fig. 2

Fig. 1 Catalog Number

Conductor Sizes

Fig. No.

Color Code Crimping Dies

Terminal Lug Only

Terminal Kit with Uncut Torpedo

Terminal Kit with Cut Off Torpedo

Concentric Round & Compressed Str. Solid

Compact Str.

LA14 LA12 LA10

LA14-TS LA12-TS LA10-TS LA8-TS LA6-TS LA4-TS LA3-TS LA2-TS LA1-TS LA1/0-TS LA2/0-TS LA3/0-TS LA4/0-TS

LA14-TS1 LA12-TS1 LA10-TS1 LA8-TS1 LA6-TS1 LA4-TS1 LA3-TS1 LA2-TS2 LA1-TS2 LA1/0-TS2 LA2/0-TS3 LA3/0-TS3 LA4/0-TS3

1 2 2 2 2 2 2 2 2 2 2 2 2

12 to 4

10-4 14

n/a

12 10

10 10

12 10

Orange

LA8 LA6 LA4 LA3 LA2 LA1

8 6 4 3 2 1

6 4 3 2 1

8 6 4

Blue

EE1-11A Kearney 840 Burndy WK840 U-K840 U249 T&B TX or 76H Alcoa AH

Orange

-

2 1

Red

1/0

White

LA1/0 LA2/0 LA3/0 LA4/0

1/0 2/0 3/0 4/0

2/0 1/0 Yellow

3/0 2/0 4/0 3/0

Gray Black

- -

4/0

Pink

LA250-TL6 3

0

250 Green

Kearney 1-1/8 Burndy 655 705, 717 Alcoa B13AH Homac-T&B Code 94 or 96 EE1-13A

LA250 LA250-TL

250

LA250-TL7 3

-

-

Green

266.8

300 350 400 500

LA350 LA350-TL LA350-TL7 3

-

350 Brown

(1) LA500-TL (1) LA500-TL7 3 (1) LA500-TL (1) LA500-TL8 3

- -

500

Aqua Aqua

LA500

-

Note: The minimum cable jacket O.D. which can be used to obtain a sealed joint is 0.220 inch; Types USE & RHW 600 volt conductors meet this need. This size does not meet class A 500 cycle EEI-NEMA rating but exceeds ampacity rating of 350 KCM XLP AA conductor and may be used for applications where 500 KCM is being used for voltage drop considerations versus ampacity.

www.cmclugs.com 513-860-4455

UNDERGROUND COMPRESSION CONNECTORS

600V

TYPE LA2 Aluminum Terminal Lugs and Tap Kits for Use on UC Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS Material: Terminals - Aluminum • Offered as individual terminal lugs or in kit form complete with a Torpedo sleeve. Kits are offered in two types: one type consists of the lug and uncut Torpedo cover; The other consists of the lug and a Torpedo sleeve factory cut, at the appropriate conductor step to match the wire size of a particular lug. • Hook-on terminal lugs have side tabs to mate with locking recesses provided in the corresponding pads of “RESIDENTIAL EEL” series types UC. • Common die terminal lugs are pre-filled with electrical joint compound and capped with color coded plugs. Field instructions and lubricant are supplied with kits. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5.

Fig. 1

3.75

3.75

Fig. 2

4.62

Catalog Number

Conductor Sizes

Approx. Wt.

Concentric Round & Compressed Str.

Fig. No.

Color Code

Crimping Dies

Terminal Kit with Uncut Torpedo

Terminal Kit with Cut Off Torpedo

Terminal Lug Only

LBS. (KG)

Solid Compact Str.

LA2-4 LA2-4TL LA2-4TL4 1

4

3

4 Orange

14 (6)

EE1-11A Kearney Burndy WK840 U-K840, U249

LA2-3 LA2-3TL LA2-3TL4 1

3

2

0 Orange

14 (6)

LA2-2 LA2-2TL LA2-2TL5 1 LA2-1 LA2-1TL LA2-1TL5 1 LA2-1/0 LA2-1/0TL LA2-1/0TL5 1 LA2-2/0 LA2-2/0TL LA2-2/0TL5 1 LA2-3/0 LA2-3/0TL LA2-3/0TL6 1 LA2-4/0 LA2-4/0TL LA2-4/0TL6 1

2 1

1

2

Red

14 (6) 14 (6) 14 (6) 13 (6) 12 (5) 11 (5)

1/0 1

White

1/0 2/0 3/0 4/0

2/0 1/0 Yellow 3/0 2/0 Gray 4/0 3/0 Black

T&B TX or 76H Alcoa 11AH

0 4/0 Pink

LA2-250 LA2-250TL LA2-250TL6 2

-

0 250 kcmil

Green

30 (14)

Kearney 1-1/8 Burndy 655 705, 717 Alcoa B13AH Homac T&B Code 94 or 96 EE1-13A

250 kcmil

LA2-250 LA2-250TL LA2-250TL7 2

-

-

Green

30 (14)

266.8 kcmil

300 kcmil

350 kcmil

LA2-350 LA2-350TL LA2-350TL7 2

-

Brown

30 (14)

350 kcmil

500 kcmil

LA2-500TL LA2-500TL7 2 400 kcmil

-

Aqua

31 (14)

LA2-500

LA2-500TL LA2-500TL8 2 500 kcmil

-

-

Aqua

31 (14)

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

600V

TYPE AL Aluminum Compression Lugs and Tap Kits for Type RD Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Kit includes crimp connector inhibited with rubber compatible sealant, rubber TS Torpedo sleeve, 3/8" button-head Allen screw with captive Belleville washer and installation instructions. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5.

Material: Lugs - Aluminum

Catalog Number

Catalog Number Lug With Torpedo

Conductor Range

Common Crimping Dies

Concentric Round Str.

Compact Str.

Solid Alum.

Lug

AL10 AL10TS

10

8 8 6 4

8 6 4 2

AL8 AL6 AL4 AL2

AL8TS AL6TS AL4TS

8 6 4

5/8 BG 243 EEI-8A

AL2TS 2 & 1 2 & 1 1/0 AL1/0 AL1/0TS 1/0 1/0 & 2/0 0 AL1/0A AL1/0ATS 1/0 1/0 & 2/0 2/0

840 249 EEI-11A

AL2/0 AL2/0TS 2/0 AL3/0 AL3/0TS 3/0 AL4/0 AL4/0TS 4/0 AL250 AL250TS 4/0-250 AL300 AL300TS 250-300 AL350 AL350TS 300-350 AL350S AL350STS 300-350

2/0 3/0

- -

4/0-250 -

250 300 350 350

- 299, 655 705, EEI 12A,13A - - 840, 845, 249, 11A -

Notes: Add suffix “HH” to specify hex head fasteners in lieu of the hex socket button-head type.

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

TYPE SLC/T/TSC Rubber Covers/Sleeves for Submersible Connectors RD, BRD, UC, UCB and UCD The following is a directory of rubber components used or supplied with various connectors: Material: EPDM Rubber 600V

Usable Internal Length Inches - (MM)

Catalog Number General Description

Fig No.

Overall Length Inches - (MM)

Cable End

Other End O.D. - IN.

SLC1 Small cover used on street light.

1

4-14.

.067 - .94 2.28 (5.8)

0

0

For single bolt UC & RD series junction con nectors. For two bolt UC series and single bolt HFS series junctions connectors. For “commercial” size two bolt terminal pad and lug connections in cluding the UCD types. For single set-screw ter minals where 1 connec tor is installed including BRD type. For single set-screw terminals where a street light tap will be installed along with a feeder or a service conductor.

TS

2

350-12

1.06 - 1.18 7.9 (201)

4.42 (112)

TL

2

500-12

1.30 - 1.50 9.34 (237)

5.97 (152)

TH

2

1000-2

1.95 - 2.20 14.31 (363)

9.42 (239)

TLS

3

500-12

1.39 - 1.50 5.86 (149)

N/A N/A

One only 350-6 and One only 4-12

TKSL

3

1.30 - 1.50

5.36 (136)

N/A N/A

1.24 - 1.40 (inc. 1.00 IPS) 3.25 (83) 1.52 - 1.72 (Inc. 1.25 IPS) 3.87 (98)

TSCSC These are three sizes of end caps used as splice chamber cable closures on TSC and HSS splice covers or equivalent. May also be used to cap conduit. TSCLC TSCHC

350-12

N/A N/A

500-12

N/A N/A

4

2.15 - 2.40 (Inc. 2.00 IPS) 4.81 (122)

750-12

N/A N/A

Fig 3

Fig 1

Fig 4

Fig 2

www.cmclugs.com 513-860-4455

SUBMERSIBLE SPLICES

Material: EPDM rubber

TYPE TSC Submersible EPDM Rubber Splice Covers

600V

• EPDM rubber covers for insulating 600 volt compression splice connections including those subject to water submersion at head pressures of three feet or less. Also suitable for direct burial. Ends have stepped sealed surfaces to accommodate a wide variety of conductor sizes. Installer cuts off these ends to fit the specific application. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5

Conductor Sealing Range

Length Inside Dia. I.D.

Maximum Size of Uncompressed Sleeve

Catalog Number

Inside Chamber Dimensions Inches (MM)

600 V Min. - Max.

O.D. in Inches Min. - Max.

O.D.

O.A.L.

TSCS

400-12

.22 - .96 4.75 (121) 1.00 (25)

.938 (24)

4.00 (102)

TSCL

500-12

.22 - 1.16 6.28 (160) 1.28 (32)

1.188 (30)

5.00 (127)

TSCH 1000-12

.22 - 1.40 9.62 (244) 1.840 (48)

1.840 (47)

8.00 (127)

www.cmclugs.com 513-860-4455

SUBMERSIBLE SPLICE COVERS

TYPE SSI Flexible Rubber Covers for Insulating

600V

• 600 volt compression splice connections including those subject to water submersion; Suitable for direct burial. Ends have stepped sealing surfaces to accommodate a wide variety of conductor sizes. • Maintains watertight integrity and full insulating value in all direct buried, underground networks, residential and overhead service joints. • Taping is eliminated and splice preparation time is significantly reduced. • Meets the performance requirements of ANSI C119.1, ANSI C119.4 and Western Underground Committee Guide 2.5.

B

Copper Cond. Range

Aluminum Cond. Range

Cable Insula tion Diameter Range

Uncompressed Splice Size O.D. O.A.L.

Catalog Number

B Inches

Diameter Inches

SSI-20 2/0-14 2/0-14 .150 - .600

4.4

0.84

0.75

3

SSI-500 500-14 500-14 .150 - 1.175 5.3

1.25

1.188

4

SSI-500L 500-14 500-14 .150 - 1.175 7.7

1.35

1.188

6

Note: SSI covers are supplied without connectors

Three Wire Twin Tap Cover

Cable Range

Length - Inches B

Catalog Number

D

E

F

DTI-500

5.3

500-14

250-14

250-14

Note: DTI-500 Supplied without connector

B

Splice Body

D

E

Splice Cap

F

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

TYPE ESC Mechanical Underground Cable Repair Splice • Dual rated for aluminum or copper conductors • Cable repair made easy - only a 5/16 Hex Wrench is needed to install this mechanical splice. • Insulation is electrical grade PVC. • Boots are watertight EPDM rubber. • Repairs 350 kcmil down to #10 wire sizes. • For installation CMC ® recommends the use of a 9" insulated Allen wrench. 600V

Conductor Range

A

B

Catalog Number

AWG Inches

Inches

ESC350-12I ESC350-18I

350-12 350-12

1.38 1.38

12 18

ESC350-24I

350-12

1.38

24

Note: Standard length is 12 inches. Available in 6 inch increments up to 48 inches. Includes watertight EPDM insulating sleeves.

A

B

www.cmclugs.com 513-860-4455

UNDERGROUND CONNECTORS

TYPE UCC Submersible Connector for Direct Burial, Below-Grade Boxes, and Network Underground. For Use with Copper Compression Lugs • Connects copper conductors through 1000 kcmil with two-hole NEMA compression lugs. • Meets the performance requirements ofANSIC119.1,ANSIC119.4 andWesternUnderground Committee Guide 2.5. • Stainless steel mounting hardware included. • Boots are watertight EPDM rubber. • Repairs 350 kcmil down to #10 wire sizes. • For installation CMC ® recommends the use of a 9" insulated Allen wrench. • A torque wrench should be used to ensure the proper torque is achieved.

Catalog Number No. of Outlets Length Width UCC-D01 2 3.00 11.00 UCC-D04 4 6.00 11.00 UCC-D06 6 9.00 11.00 UCC-D08 8 12.00 11.00 UCC-D10 10 15.00 11.00 UCC-D12 12 18.00 11.00

Material: Body - Tin Plated Copper Hardware - Stainless Steel, Captive Belleville and Flat Washers Insulation - EPDM Rubber Uses the TH Rubber Rocket

UCC Connector

BAUCCB

• THSleeves (sold separately) allowfor awaterproof seal up to 1000 kcmil. • Ceneterformcompression lugs available incommon 500, 750 and 1000mcm. • BAUCCB Mounting Bracket - 2 required, per assembly. • Unique time-saving, adjustablemountingbracket (sold separately) allows for quick installation and support of the connector. • Eliminates twisted andbent connections that allow forgappingand improper sealingaround theconductor. • Supports heavy copper connectors and conductor.

BAUCCB

TH Sleeves

BAUCCB Mounting Bracket

www.cmclugs.com 513-860-4455

LAY-IN PEDESTAL CONNECTORS

TYPE LI DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Unique lay-in feature reduces frustration of feeding multiple conductors through standard connectors. • Each outlet has a removable “keeper” that allows conductors to be laid into the outlet, solving the problem of trying to bend in confined areas. The “keeper” is then slid over the conductor and the set-screws are tightened. It is fast and easy at initial installations, and for later service additions. • Connectors are fabricated from 6061-T6 aluminum alloy and clear plated for high conductivity and strength. • Fully tested ANSI C119.4 for Class ‘A’ connectors. • CMC® recommends the use of a 9” insulated wrench for installations. 600V

L

H

W

Catalog Number LI350-6

Conductor Range kcmil

Number Cond.

L

W

H

Cover

6 6 6 6 4

350-10 350-10 600-10 600-10

6.912 6.912 8.375 8.375 6.812

1.250 1.250 1.250 1.250 2.500

1.750 1.750 2.000 2.000 3.000

PEDCA PEDCA

**LI350-6-1

LI600-6

PEDCA-600 PEDCA-600

**LI600-6-1 *LI1000-4

1000-1/0

DB-4

*Two set-screws per conductor **Connector includes two 1/4 - 20 mounting holes

PEDCA

Cover made with Clear, hard Lexan.

www.cmclugs.com 513-860-4455

ABOVE-GRADE SECONDARY CONNECTORS

TYPE NA Secondary Connectors for Above-Grade Use DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Clear plated for low-contact resistance. • Fully tested to ANSI C119.4 for Class ‘A’ connectors. • Supplied with radial-tipped set-screws. • 105 º C rated black plastisol cover available. • Connector fabricated from 6061–T6 aluminum alloy for conductivity and strength.

600V

• Includes CO-OX oxide inhibitor in all conductor holes. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC® recommends the use of a 9” insulated Allen wrench.

H W L Cover Number Dimensions - Inches

Cond. Range AWG

Catalog Number No. of Cond.

L

NA250-3I

3

250-12 1.13 0.88 2.75 NC3-250

H

NA250-4I

4

250-12 1.13 0.88 3.63 NC4-250

W

NA250-5I

5

250-12 1.13 0.88 4.5 NC6-250

NA250-6I

6

250-12 1.13 0.88 5.38 NC6-250

NA250-8I

8

250-12 1.13 0.88 7.13 NC8-250

NA350-3I

3

350-12 1.25 1.00 2.88 NC3-350

NA350-4I

4

350-12 1.25 1.00 3.79 NC4-350

NA350-5I

5

350-12 1.25 1.00 4.7 NC6-350

NA350-6I

6

350-12 1.25 1.00 5.61 NC6-350

NA350-8I

8

350-12 1.25 1.00 7.43 NC8-350

Note:

1. For omission of CO-OX oxide inhibitor, delete suffix - “I” 2. Street light tap available - add suffix “SL” to catalog number. 3. To order connector and cover add “C” to description. eg: NA350-6CI

www.cmclugs.com 513-860-4455

ABOVE-GRADE SECONDARY CONNECTORS

TYPE NA Secondary Connectors for Above-Grade Use DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

600V

L

• Clear plated for low-contact resistance. • Fully tested to ANSI C119.4 for Class ‘A’ connectors. • Supplied with radial-tipped set-screws. • 105°C Rated black plastisol cover available. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Includes CO-OX oxide inhibitor in all conductor holes. • Each unit individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC® recommends the use of a 9” insulated Allen wrench.

H

W

Cond. Range AWG MM2 500-10 240-4 500-10 240-4 500-10 240-4 500-10 240-4 500-10 240-4 750-2 300-25 750-2 300-25 750-2 300-25 750-2 300-25 750-2 300-25

H

W L

Catalog Number

No. of Cond.

Cover Number

Dimensions - Inches Dimensions - (mm)

1.406 41.4 1.406 41.4 1.406 41.4 1.406 41.4 1.406 41.4 1.88 47.75 1.88 47.75 1.88 47.75 1.88 47.75 1.88 47.75

1.00 25.4 1.00 25.4 1.00 25.4 1.00 25.4 1.00 25.4

3.65 92.71

NA500-3I

3

NC3-500

4.84 122.94 6.03 153.16 7.22 183.39 9.59 243.57 4.18 106.17 5.49 139.45 6.8 172.72 8.11 205.99 10.73 272.54

NA500-4I

4

NC4-500

NA500-5I

5

NC6-500

NA500-6I

6

NC6-500

NA500-8I

8

NC8-500

1.38 35.05 1.38 35.05 1.38 35.05 1.38 35.05 1.38 35.05

NA750-3I

3

NC3-750

NA750-4I

4

NC4-750

NA750-5I

5

NC6-750

NA750-6I

6

NC6-750

NA750-8I

8

NC8-750

Note:

1. For omission of CO-OX oxide inhibitor, delete suffix - “I” 2. Street light tap available - add suffix “SL” to catalog number. 3. To order connector and cover add “C” to description. eg: NA350-6CI

www.cmclugs.com 513-860-4455

ABOVE-GRADE SECONDARY CONNECTORS

TYPE ND Heavy-Duty Secondary Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • Clear plated for low-contact resistance. • Fully tested to ANSI C119.4 for Class ‘A’ connectors. • Supplied with radial-tipped set-screws. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength.

600V

• Includes CO-OX oxide inhibitor in all conductor holes. • Each unit is individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC®recommends the use of a 9” insulated Allen wrench.

H

W L

Cond. Range AWG MM2 250-12

Catalog Number

No. of Cond.

Dimensions - Inches Dimensions - (mm)

1.36

1.75

3.63

ND250-4I

4

120-4

34.93

44.45 92.20

250-12

1.36

1.75

5.38

ND250-6I

6

120-4

34.93

44.45 136.65

L

250-12

1.36

1.75

7.13

ND250-8I

8

120-4

34.93

44.45 181.10

350-12

1.38

1.86

3.79

ND350-4I

4

H

185-4

35.05

47.63 96.27

350-12

1.38

1.86

5.61

ND350-6I

6

185-4

35.05

47.63 142.49

W

350-12

1.38

1.86

7.43

ND350-8I

8

185-4

35.05

47.63 188.72

500-10

1.50

2.25

4.84

ND500-4I

4

240-4

38.10

57.15 122.94

500-10

1.50

2.25

7.22

ND500-6I

6

240-4

38.10

2.25 183.39

500-10

1.50

2.25

9.59

ND500-8I

8

240-4 750-2

38.10

2.25 243.59

2.50

2.00

5.49

ND750-4I

4

300-25 63.50

57.15 139.45

750-2

2.50

2.00

8.11

ND750-6I

6

300-25 63.50

57.15 205.99

750-2

2.50

2.00

10.73

See Accessories for covers.

ND750-8I

8

300-25 63.50

57.15 272.54

1000-2

2.50

2.00

6.58

ND1000-4I

4

500-25 63.50

57.15 167.13

1000-2

2.50

2.00

9.83

ND1000-6I

6

500-25 63.50

57.15 249.68

1000-2

2.50

2.00

13.08

ND1000-8I

8

500-25 63.50

57.15 332.23

Note: For omission of CO-OX oxide inhibitor, delete suffix - “I”

www.cmclugs.com 513-860-4455

INSULATED SECONDARY CONNECTORS

TYPE NACC Clear Insulated Secondary Connectors

90º C Rating (486B listed).

RUS Approved

DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

600V

• Clear plated for low-contact resistance. • Fully tested to ANSI C119.4 for Class ‘A’ connectors. • Supplied with radial-tipped set-screws. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. • Includes CO-OX oxide inhibitor in all conductor holes.

• Each unit is individually wrapped and labeled for ease of identification and cleanliness. • For installation, CMC® recommends the use of a 9” insulated Allen wrench.

PATENTED

Catalog Number Number of Cond. Cond. Range H W L NACC250-2SI 2 2

NACC250-3SI NACC250-4SI NACC250-5SI NACC250-6SI NACC250-8SI NACC350-2SI NACC350-3SI NACC350-4SI NACC350-5SI NACC350-6SI NACC350-7SI NACC350-8SI NACC600-2SI NACC600-3SI NACC600-4SI NACC600-5SI NACC600-6SI NACC600-7SI NACC600-8SI

3 4 5 6 8 2 3 4 5 6 7 8 2 3 4 5 6 7 8

3

3.90 4.90 5.80 7.60 2.20 3.10 4.00 5.00 5.90 6.90 7.70 2.70 4.00 5.25 6.60 7.80 8.80

250-12 2.13 2.06

350-12 2.31 2.50

W

L

H

600-4 2.75 2.50

10.40

Note: Available in black for UV protection. Add“black” to the end of the catalog number.

www.cmclugs.com 513-860-4455

FLEX TAP INSULATED BAR CONNECTORS

TYPE NACC Clear Insulated Secondary Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

90º C Rating (486B listed). 600V

• CMC® Flex tap is available in two through eight conductor configurations in five conductor sizes. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength.

• Connector is encapsulated in clear PVC rated at 240 volts per mil. • Clear cover allows visual inspection of conductors during installation. • Fully tested to ANSI C119.4 for Class ‘A’ connectors.

Fig. 1 Top View

Fig. 2 Top View

Fig. 3 Top View

PATENTED

H W L

Cond. Range AWG Alum - Copper

Catalog Number

Figure Number

No. of Cond.

Dimensions - Inches

NACC4-2A 2 NACC4-3A 2 NACC4-2S 1 NACC4-3S 1 NACC4-4S 1 NACC4-5S 1 NACC4-6S 1 NACC4-8S 1 NACC4-2B 3 NACC4-3B 3 NACC4-4B 3 NACC4-5B 3 NACC4-6B 3 NACC4-8B 3

2 3 2 3 4 5 6 8 2 3 4 5 6 8

1.21 1.81 1.21 1.81 2.40 3.00 3.60 4.78 1.21 1.81 2.40 3.00 3.60 4.78

4-14

1.12 1.50

4-14

1.12 1.06

4-14

1.12 1.50

Note: Available in black for UV protection. Add“black” to the end of the catalog number.

www.cmclugs.com 513-860-4455

FLEX TAP INSULATED BAR CONNECTORS

TYPE NACC Clear Insulated Secondary Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS • CMC® Flex tap is available in two through eight conductor configurations in five conductor sizes. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength. 90º C Rating (486B listed). 600V

• Connector is encapsulated in clear PVC rated at 240 volts per mil. • Clear cover allows visual inspection of conductors during installation. • Fully tested to ANSI C119.4 for Class ‘A’ connectors.

Fig. 1 Top View

Fig. 2 Top View

Fig. 3 Top View

H W L Dimensions - Inches

Cond. Range AWG Alum - Copper

No. of Cond.

Catalog Number Figure Number

NACC2/0-2A 2

2 3 2 3 4 5 6 8 2 3 4 5 6 8

1.21 1.81 1.21 1.81 2.40 3.00 3.60 4.78 1.21 1.81 2.40 3.00 3.60 4.78

2/0-14

1.20 1.56

NACC2/0-3A NACC2/0-2S NACC2/0-3S NACC2/0-4S NACC2/0-5S NACC2/0-6S NACC2/0-8S NACC2/0-2B

2 1 1 1 1 1 1 3

2/0-14

1.20 1.12

NACC2/0-3B 3

NACC2/0-4B

3

2/0-14

1.20 1.56

NACC2/0-5B 3

NACC2/0-6B NACC2/0-8B

3 3

Note: Available in black for UV protection. Add“black” to the end of the catalog number.

www.cmclugs.com 513-860-4455

FLEX TAP INSULATED BAR CONNECTORS

TYPE NACC Clear Insulated Secondary Connectors

DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

90º C Rating (486B listed).

600V

• CMC® Flex tap is available in two through eight conductor configurations in five conductor sizes. • Connector fabricated from 6061-T6 aluminum alloy for conductivity and strength.

• Connector is encapsulated in clear PVC rated at 240 volts per mil. • Clear cover allows visual inspection of conductors during installation. • Fully tested to ANSI C119.4 for Class ‘A’ connectors.

Fig. 1 Top View

Fig. 2 Top View

PATENTED

H L Dimensions - Inches 2.13 2.60 1.87 2.13 2.60 2.75 2.13 2.60 1.87 2.13 2.60 2.75 2.13 2.60 3.62 2.13 2.60 4.50 2.13 2.60 5.37 2.13 2.60 7.12 W

Catalog Number

Fig. No.

No. of Cond.

Cond. Range AWG Alum - Copper

NACC250-2A 1

2 3 2 3 4 5 6 8

250 - 12 250 - 12 250 - 12 250 - 12 250 - 12 250 - 12 250 - 12 250 - 12

NACC250-3A

1

NACC250-2B 2

NACC250-3B

2

NACC250-4B 2 NACC250-5B 2 NACC250-6B 2 NACC250-8B 2

Note: Available in black for UV protection. Add“black” to the end of the catalog number.

www.cmclugs.com 513-860-4455

FLEX TAP INSULATED BAR CONNECTORS

TYPE NACC Clear Insulated Secondary Connectors DUAL-RATED CONNECTORS FOR ALUMINUM OR COPPER CONDUCTORS

90º C Rating (486B listed).

600V

• CMC® Flex tap is available in two through eight conductor configurations in five conductor sizes. • Connector is fabricated from 6061-T6 aluminum alloy for conductivity and strength.

• Connector is encapsulated in clear PVC rated at 240 volts per mil. • Clear cover allows visual inspection of conductors during installation. • Fully tested to ANSI C119.4 for Class ‘A’ connectors.

Fig. 2 Top View

Fig. 1 Top View

PATENTED

H W L Dimensions - Inches 2.13 2.60 1.87 2.13 2.60 2.75 2.13 2.60 1.87 2.13 2.60 2.75 2.13 2.60 3.62 2.13 2.60 4.50 2.13 2.60 5.37 2.13 2.60 7.12

Catalog Number

Fig. No.

No. of Cond.

Cond. Range AWG Alum. - Copper

NACC350-2A 1 NACC350-3A 1 NACC350-2B 2 NACC350-3B 2 NACC350-4B 2 NACC350-5B 2 NACC350-6B 2 NACC350-8B 2

2 3 2 3 4 5 6 8

350 - 12 350 - 12 350 - 12 350 - 12 350 - 12 350 - 12 350 - 12 350 - 12

Note: Available in black for UV protection. Add“black” to the end of the catalog number.