Killark Full Catalog
ENCLOSURES B7E SERIES
JUNCTION BOXES
Figure 1
MODIFICATIONS
SUFFIX NUMBER
DESCRIPTION
KIT-251 KIT-252
100 amp ground lug 225 amp ground lug
cCSAus, ATEX, IEC Ex drain and breather installed Class I Groups C & D & Ex d IIB, Type 4, 4X, IP66
SU3B-QA
UL and CSA drain and breather installed Class I Groups B, TYPE 4, 4X External gray powder coated epoxy paint
SU3B-4X
SU9PEEX
SU14
Fungus proof internally Special paint- specify Do not paint enclosure
SU9
SU93
TOE PLATE KIT
Door guide plate to assist in aligning and installing cover bolts
B7E JUNCTION BOXES AND ENCLOSURES
PAN CATALOG NUMBER WIDTH (J)
CATALOG NUMBER
LENGTH (K)
Figure 2
B7EA B7EB B7EC B7ED B7EE B7EF B7EG B7EH B7EK B7EL B7EM B7EN B7EP B7EQ
19919 19920 18245 19921 19923 18472 19924 19925 19926 19927 19928 19929
5”
11-3/4” 16-3/4” 13-3/4” 19-3/8” 20-3/8” 21-1/4”
8-1/4” 6-1/4” 8-3/8” 6-3/8” 11-5/8”
10”
28”
15-3/8”
28-3/8”
11” 11” 11” 11” N/A N/A
18” 27” 39” 47” N/A N/A
— —
Internal Mounting Pan Thickness is 1/8” except on B7EJ it is 3/16” thick.
B7E JUNCTION BOXES AND ENCLOSURES
DIMENSIONS
MAXIMUM CONDUIT SIZE
MAXIMUM NUMBER OF OPERATORS
CATALOG NUMBER
NOMINAL INSIDE
OUTSIDE LENGTH (E)
MOUNTING
DRAWING FIGURE
WIDTH (A)
LENGTH (B)
DEPTH (C) 6-11/16”
WIDTH (D)
DEPTH (F)
WIDTH (G)
LENGTH (H)
TOP AND BOTTOM SIDES
B7EA B7EB B7EC B7ED B7EE B7EF B7EG B7EH B7EK B7EL B7EM B7EN B7EP B7EQ
6-1/2”
13-1/2” 18-1/2” 15-1/2” 21-3/4” 22-3/4” 29-3/4” 29-3/4” 21”
11”
18” 23” 20”
9-1/8” 9-1/8” 9-1/8” 9-1/8”
3-5/8”
16-3/8” 21-3/8” 18-3/8” 23-7/8” 24-5/8” 25-5/8” 32-5/8” 32-5/8”
1 1 1 1 1 1 1 1 2 2 2 2 1 2
1-1/2” 1-1/2” 1-1/2” 1-1/2”
1” 1” 1” 1” 2” 4” 4” 4”
4 rows of 2 = 8 7 rows of 3 = 21 5 rows of 2 = 10 8 rows of 3 = 24 8 rows of 2 = 16 8 rows of 4 = 32 8 rows of 3 = 24 9 rows of 5 = 45 6 rows of 4 = 24 9 rows of 4 = 36 14 rows of 4 = 56 17 rows of 4 = 68
10”
6-5/8”
14-1/2”
7” 5” 7” 5”
8”
6-11/16” 12-1/2” 6-11/16” 14-1/2” 8-5/16” 12-1/2”
10”
25-1/2” 26-1/4” 27-1/4” 34-1/4” 34-1/4” 24-3/4” 33-3/8” 45-3/8” 54-3/8” 8-1/16”
8”
10-3/4”
2” 4” 5” 5” 3” 3” 3” 3” 1”
13” 12” 17” 13” 13” 13” 13”
8-3/8” 8-7/8”
17-7/8” 16-1/2”
11”
10-3/8”
11-1/2” 11-7/8” 9-1/2” 9-1/2” 9-1/2” 9-1/2” 6-5/16”
9”
8-11/16” 21-1/2”
14”
20” 29” 41” 50”
6-5/8” 6-5/8” 6-5/8” 6-5/8” 5-1/16” 6-5/16”
17-1/2” 17-1/2” 17-1/2” 17-1/2” 5-3/4” 8-1/8”
15-1/4” 15-1/4” 15-1/4” 15-1/4” 3-1/8”
13” 21” 33” 42”
1-1/2” 1-1/2” 1-1/2” 1-1/2”
3-5/8” 4-1/4”
5-13/16” 9-3/16”
8-1/8” 7-1/2”
1”
1 row of 2 = 2 1 row of 4 = 4
13-1/16” 7-13/16” 6-3/8”
1-1/2”
1-1/2”
All Conduits must be sealed within 18” when used in Group B Locations. Operator spacing is 2-1/2” to except on B7EG & B7EH spacing is 3” to . Internal Mounting Pan Thickness is 1/8”. Consult Killark for drawing details before layout of cover devices. Maximum number of “G” series control operators permitted in cover, down + across = total.
www.hubbell.com/killark
E73
Made with FlippingBook Digital Publishing Software