Substation Connectors (Combined)

SUBSTATION TEES

HUBBELL ® Power Systems

EHV TEE-TAPS COMPRESSION CABLE TO PAD-OPEN RUN AAC, ACAR AND ACSR CONDUCTOR

ALUMINUM ORT21

Aluminum compression tee connectors are designed for corona free service at 500 KV. Single cable diame ter under 1.76 inch for 345 KV and 2.50 inch diameter for 500 KV may not be corona free unless conductors are bundled. Hardware shields and hardware must be ordered separately. Contact sealant is recommended.

Tapers and pad are coated with protective strippable plastic. Pad holes have NEMA spacing.

Material:

Seamless Extruded Aluminum Alloy Tube Pad–Pure Cast Aluminum

Add suffix: “-HS” for one hardware shield, and “-HS2” for two hardware shields.

345 kV AND 500 kV LINE-TO-LINE APPLICATIONS

CONDUCTOR RANGE (1)

PAD DETAILS LENGTH BEFORE COMPR. IN (MM) BOLT HOLES WIDTH IN (MM)

MINIMUM PRESS (TONS)

NET WEIGHT LB (KG)

CATALOG NUMBER

O.D. (IN.)

AAC SIZE KCMIL

ACSR SIZE KCMIL (STR)

DIE SIZE (2)

3.0 (76) 4.0 (102) 3.0 (76) 4.0 (102) 3.0 (76) 4.0 (102) 3.0 (76) 4.0 (102) 3.0 (76) 4.0 (102) 4.0 (102)

17.3 (439) 18.3 (465) 18.5 (470) 19.5 (495) 19.8 (503) 20.8 (528) 20.7 (526) 21.7 (551) 21.6 (549) 22.9 (574)

795, 800, 874.5, 900, 954

715.5 (24/7) (26/7) (30/19), 795 (24/7) (26/7) (45/7) (54/7), 795 (36/1), 900 (45/7)

ORT2112 ORT2112D

1.026 - 1.131 (26.1 -28.7)

3.1 (1.35) 3.3 (1.50)

4

12CD 60

13CD or 30AH

1000, 1003.5

795 (30/19)

4

ORT2113 ORT2113D

1.140 - 1.235 (29.0 - 31.4)

3.6 (1.57) 3.8 (1.66)

60

900 (54/7) 954 (45/7) (54/7), 1033.5 (36/1) (45/7) 954 (30/19), 1033.5 (54/7), 1113 (45/7) (54/19), 1192.5 (45/7)

1100, 1113

4

13CD

4.6 (2.00) 4.8 (2.09) 5.5 (2.40) 5.7 (2.48)

1192.5, 1200 1250, 1272, 1300 1351.5, 1400 1431, 1500 1510.5

ORT2114 ORT2114D

1.236 - 1.330 (31.5 - 33.8)

14CD or 34AH

4

60

EHV 34

1192.5 (54/19), 1272 (45/7) (54/19), 1351.5 (45/7) (54/19)

ORT2115 ORT2115D

1.331 - 1.425 (33.9 - 38.2)

15CD or 36AH

4

60

ORT2116 ORT2116D

1.425 - 1.520 (36.3 - 38.6)

1590, 1600, 1700

1431 (45/7) (54/19), 1510.5 (45/7) (54/19), 1590 (45/7)

16CD or 38AH

6.1 (2.66) 6.3 (2.74)

4

60

1590 (54/19), 1780 (84/19), 1869 (68/7)

1.521 - 1.615 (38.7 - 41.0)

1750, 1800, 1900

23.5 (597)

17CD or 40AH

7.8 (3.40)

ORT2117

4

60

2000, 2250, 2300

2034.5 (72/7), 2057 (76/19) 2167 (72/7)

19CD or 44AH 100

4

1.630 - 1.805 (41.4 - 45.8)

4.0 (102)

25.4 (645)

10.2 (4.43)

ORT2119

2156 (84/19), 2312 (76/19)

4

19CD

NOTES: (1) These tee taps are also approved application on AAAC and ACAR conductors within the diameter ranges listed. (2) Hex dies not available for some sleeve & conductor combinations. If no AH die listed for conductor, use only the CD die shown. (3) Install with Fargo type UJC or, for lowest resistance connection, type HTJC inhibitor compound.

ANDERSON ™

HUBBELL ® POWER SYSTEMS

FARGO ®

October 2016

Made with FlippingBook flipbook maker