Quadri*Sil Insulators Extra High Leak (EHL) Supplemental Catalog (24)

Section Length High Leak Design

Suspension Insulators Mechanical Ratings SML = 25 kip/120 kN RTL = 12.5 kip/60 kN Rod Diameter: 5/8" (16 mm)

Section Length Standard Design

ANSI Values I lu

IEC Values

Strike Distance inches (mm)

Nominal Polymer Length inches

Section Length inches (mm)

Leakage Distance inches (mm)

Selection Guide: Typical Line Voltage, kV

60-Hz 1-minute Wet Withstand (kV)

Catalog Numbers ANSI / IEC

Impulse Positive Withstand (kV)

Critical Impulse Negative (kV)

Impulse Negative Withstand (kV)

60-Hz Dry Flashover (kV)

60-Hz Wet Flashover (kV)

Critical Impulse Positive (kV)

69 110 132 161 220 330 400

Catalog Numbers ANSI S030022E2010 S030024E2010 S030029E2010 S030036E2010 S030043E2010 S030047E2010 S030052E2010 S030056E2010 S030061E2010 S030065E2010 S030068E2010 S030072E2010 S030077E2010 S030081E2010 S030086E2010 S030090E2010 S030095E2010 S030100E2010 S030104E2010 S030109E2010 S030113E2010 S030118E2010 S030120E2010 S030125E2010 S030129E2010 S030134E2010 S030138E2010 S030143E2010 S025022E2010 / S025024E2010 / S025029E2010 / S025036E2010 / S025043E2010 / S025047E2010 / S025052E2010 / S025056E2010 / S025061E2010 / S025065E2010 / S025068E2010 / S025072E2010 / S025077E2010 / S025081E2010 / S025086E2010 / S025090E2010 / S025095E2010 / S025100E2010 / S025104E2010 / S025109E2010 / S025113E2010 / S025118E2010 / S025120E2010 / S025125E2010 / S025129E2010 / S025134E2010 / S025138E2010 / S025143E2010 /

S120022E2010 S120024E2010 S120029E2010 S120036E2010 S120043E2010 S120047E2010 S120052E2010 S120056E2010 S120061E2010 S120065E2010 S120068E2010 S120072E2010 S120077E2010 S120081E2010 S120086E2010 S120090E2010 S120095E2010 S120100E2010 S120104E2010 S120109E2010 S120113E2010 S120118E2010 S120120E2010 S120125E2010 S120129E2010 S120134E2010 S120138E2010 S120143E2010

22 24 29 36 43 47 52 56 61 65 68 72 77 81 86 90 95

34.4 36.7 41.3 48.1 54.9 59.5 64.1 68.6 73.2 77.7 80.0 84.6 89.1 93.7 98.2

(874.8) (932.7) (1048.4) (1222.0) (1395.6) (1511.3) (1627.0) (1742.7) (1858.5) (1974.2) (2032.1) (2147.8) (2263.5) (2379.2) (2494.9) (2610.7) (2726.4) (2842.1) (2957.8) (3073.6) (3189.3) (3305.0) (3362.9) (3478.6) (3594.3) (3710.0) (3825.7) (3941.5)

24.8 27.1 31.6 38.4 45.3 49.8 54.4 59 63.5 68.1 70.3 74.9 79.5 84 88.6 93.1 97.7

96 105 124 153 182 201 221 240 259 278 288 307 327 346 365 384 404 423 442 461 481 500 509 529 548 567 586 606

(2438.4) (2667.0) (3149.6) (3886.2) (4622.8) (5105.4) (5613.4) (6096.0) (6578.6) (7061.2) (7315.2) (7797.8) (8305.8) (8788.4) (9271.0) (9753.6) (10261.6) (10744.2) (11226.8) (11709.4) (12217.4) (12700.0) (12928.6) (13436.6) (13919.2) (14401.8) (14884.4) (15392.4)

250 275 315 380 445 490 535 575 620 665 685 730 775 820 865 910 955

235 260 295 360 420 465 500 540 575 615 630 665 700 735 770 800 835 865 895 925 955 985

420 455 520 620 725 795 860 930 995

390 430 505 615 730 805 880 950

175 195 220 270 315 345 375 405 430 460 470 495 525 550 575 600 625 645 670 690 715 735 750 765 790 810 825 845

(629.9) (688.3) (802.6) (975.4) (1150.6) (1264.9) (1381.8) (1498.6) (1612.9) (1729.7) (1785.6) (1902.5) (2019.3) (2133.6) (2250.4) (2364.7) (2481.6) (2595.9) (2712.7) (2827.0) (2943.9) (3060.7) (3116.6) (3233.4) (3347.7) (3464.6) (3581.4) (3695.7)

375 405 465 555 650 715 770 835 895 955 990

350 385 450 550 655 720 790 855 920 985

1025 1095 1130 1205 1275 1345 1415 1485 1555 1620 1690 1755 1820 1890 1920 1985 2050 2115 2180 2240

1065 1100 1165 1235 1305 1370 1440 1505 1575 1645 1710 1780 1850 1880 1950 2015 2085 2155 2220

1015 1080 1145 1210 1270 1335 1395 1455 1520 1575 1635 1700 1725 1785 1845 1900 1960 2015

1045 1110 1170 1230 1295 1350 1415 1480 1535 1600 1665 1690 1755 1810 1875 1935 1995

102.8 107.3 111.9 116.5 121.0 125.6 130.1 132.4 137.0 141.5 146.1 150.6 155.2

100 104 109 113 118 120 125 129 134 138 143

102.2 106.8 111.3 115.9 120.5 122.7 127.3 131.8 136.4 141 145.5

1000 1045 1090 1135 1180 1200 1245 1290 1340 1385 1430

1000 1025 1055 1080 1105 1130

ANSI Values

IEC Values

Leakage Distance inches (mm)

Section Length inches (mm)

Strike Distance inches (mm)

Nominal Polymer Length inches

Selection Guide: Typical Line Voltage, kV

60-Hz 1-minute Wet Withstand (kV)

60-Hz Wet Flashover (kV)

Critical Impulse Negative (kV)

60-Hz Dry Flashover (kV)

Impulse Positive Withstand (kV)

Critical Impulse Positive (kV)

Impulse Negative Withstand (kV)

69 110 132 161 220 330 400

24.8 27.1 31.6 38.4 45.3 49.8 54.4 59 63.5 68.1 70.3 74.9 79.5 84 88.6 93.1 97.7

(629.9) (688.3) (802.6) (975.4) (1150.6) (1264.9) (1381.8) (1498.6) (1612.9) (1729.7) (1785.6) (1902.5) (2019.3) (2133.6) (2250.4) (2364.7) (2481.6) (2595.9) (2712.7) (2827.0) (2943.9) (3060.7) (3116.6) (3233.4) (3347.7) (3464.6) (3581.4) (3695.7)

96 105 124 153 182 201 221 240 259 278 288 307 327 346 365 384 404 423 442 461 481 500 509 529 548 567 586 606

(2438.4) (2667.0) (3149.6) (3886.2) (4622.8) (5105.4) (5613.4) (6096.0) (6578.6) (7061.2) (7315.2) (7797.8) (8305.8) (8788.4) (9271.0) (9753.6) (10261.6) (10744.2) (11226.8) (11709.4) (12217.4) (12700.0) (12928.6) (13436.6) (13919.2) (14401.8) (14884.4) (15392.4)

22 24 29 36 43 47 52 56 61 65 68 72 77 81 86 90 95

34.4 36.7 41.3 48.1 54.9 59.5 64.1 68.6 73.2 77.7 80.0 84.6 89.1 93.7 98.2

(874.8) (932.7) (1048.4) (1222.0) (1395.6) (1511.3) (1627.0) (1742.7) (1858.5) (1974.2) (2032.1) (2147.8) (2263.5) (2379.2) (2494.9) (2610.7) (2726.4) (2842.1) (2957.8) (3073.6) (3189.3) (3305.0) (3362.9) (3478.6) (3594.3) (3710.0) (3825.7) (3941.5)

250 275 315 380 445 490 535 575 620 665 685 730 775 820 865 910 955

235 260 295 360 420 465 500 540 575 615 630 665 700 735 770 800 835 865 895 925 955 985

420 455 520 620 725 795 860 930 995

390 430 505 615 730 805 880 950

175 195 220 270 315 345 375 405 430 460 470 495 525 550 575 600 625 645 670 690 715 735 750 765 790 810 825 845

375 405 465 555 650 715 770 835 895 955 990

350 385 450 550 655 720 790 855 920 985

1025 1095 1130 1205 1275 1345 1415 1485 1555 1620 1690 1755 1820 1890 1920 1985 2050 2115 2180 2240

1065 1100 1165 1235 1305 1370 1440 1505 1575 1645 1710 1780 1850 1880 1950 2015 2085 2155 2220

1015 1080 1145 1210 1270 1335 1395 1455 1520 1575 1635 1700 1725 1785 1845 1900 1960 2015

1045 1110 1170 1230 1295 1350 1415 1480 1535 1600 1665 1690 1755 1810 1875 1935 1995

102.8 107.3 111.9 116.5 121.0 125.6 130.1 132.4 137.0 141.5 146.1 150.6 155.2

102.2 106.8 111.3 115.9 120.5 122.7 127.3 131.8 136.4 141 145.5

100 104 109 113 118 120 125 129 134 138 143

1000 1045 1090 1135 1180 1200 1245 1290 1340 1385 1430

1000 1025 1055 1080 1105 1130

Notes : n Dimensional and electrical values displayed in main table are for an insulator with Y-clevis and Ball end fittings. n For voltages above 400 kV, other section lengths, or end fitting combinations, please contact your HPS representative. n Electrical values are without corona ring. For voltages equal to or greater than 220 kV, refer to page 12 for corona rings and associated physical/electrical changes to the above data. Dimensions are within allowable tolerances as specified by IEC 61109 and ANSI C29.12.

Section Length Adjustment Table, Base End Fittings: Y-clevis-Ball (201)

Length Change inches (mm)

Top Fitting

Bottom Fitting Top and Bottom End Fitting Digits (ā€œeā€ & ā€œfā€) in Catalog Number

Y-Clevis Eye Eye

Eye ANSI 52-5 Ball Eye ANSI 52-5 Ball IEC 16 mm Ball Eye ANSI 52-5 Ball

200 001 000 301 A07 400 401

1.62 (41) 0.02 (0) 1.64 (42) -1.15 (-29) -0.03 (-1) 0.82 (21) -0.8 (-20)

ANSI 52-5 Socket IEC 16 mm Socket ANSI 52-6 Clevis ANSI 52-6 Clevis

To determine the section length for an insulator with a different end fitting combination, please add or subtract the displayed length change in the table above. For configurations not shown, use the Catalog Number Key or contact your HPS representative.