Polycast - Trench Drains (PC-1)
CHOOSING A SYSTEM
Hydraulic Capacity To ensure that the correct trench drain is selected for each site, several factors should be evaluated. The most important of these is hydraulic performance, or the ability of the drain to evacuate water without flooding.
p Calculate Flow The catch basin or drain outlet must be sized to meet the maximum amount of water to be evacuated from the site. This model is designed for rainfall run-off, but can be easily converted to industrial or overflow drainage. To calculate flow (Q) in gpm, the following parameters are needed:
C
B
Drainage area = length x width (A x B) Rainfall intensity in inches per hour (C)
A
Q
Area (AxB) x Rainfall (C) 60 (minutes) x 1.6 (conversion to gallons)
Q (GPM) =
Flow capacity for POLYCAST ® drains
400 450 500 550 350 300 100 150 200 800 850 750 900 950 700
HYDRAULIC CAPACITY 600 650
600 SERIES W/EXTENDERS
600 SERIES
Flow Rate (gpm) 250
50
0
0
20
40
60
80
100
120
Length of Run (ft) From Catch Basin
Catch Basin
Deepest Channel
Shallowest Channel
6