Hipotronics Product Catalog (2/24/21)

TECHNICAL SPECIFICATIONS Model #

840PL-HD 0.4 – 40kV

880PL-HD 0.4 – 80kV

Voltage Current Polarity

System Output

10mA

Negative Output, Positive Ground ± 1.5% of Reading ± 0.2% F.S.

Voltage & Current Measurement Accuracy Voltage Resolution Current Resolution Insulation Resistance Measurement Range

100V 0.1  A

10kΩ – 40GΩ  1% of scale

IR Accuracy IR Resolution Duty Cycle Dimensions (W x D x H) Input

10k 

90-264VAC, 45-65Hz, 900VA 1 hour ON / 1 hour OFF

Net

20in x 14in x20in (50cm x 35cm x 51 cm) 24in x 19in x 23in (61cm x 48cm x 58cm)

Shipping

Net

78lbs (36kg) 91lbs (42kg)

Weight

Shipping

Emergency Stop

Interlock Hand-switch (optional) External Warning Lamp (optional) Interlock Foot Pedal (optional)

Visual Warning Indicators

Safety Features

External Interlock

Audible Warning Indicator

Display Interfaces

7” TFT , 800 x 480, Color Touch Screen

USB 2.0 for Memory Stick

Output Data Format Calibration Interval Languages ECCN: 3A992.A

CSV

1 year recommended

English, Spanish, Portuguese, French, German, Mandarin

HTS: 9030.39.0100

Electronic Components

High Voltage Components

Temperature -10°C … +50°C -20°C … +70°C

Humidity (r.h. non-condensing)

Temperature -10°C … +50°C -20°C … +55°C

Humidity (r.h. non-condensing)

Operation Storage

5 … 95% 5 … 95%

5 … 90% 5 … 90%

SCOPE OF SUPPLY

STANDARD OPTIONS

HHDA13-280 – 120kV rated grounding stick HH-HS-DI – Hand operated interlock switch HH-FS-DI – Foot operated interlock switch

25ft HV output cable with clamp 25ft HV return cable with clamp 25ft HV ground with clamp

HH-WARN-DI – Safety Strobe light with magnetic base

6ft input power cord

EXT-WARN-1 – One-year extended warranty

Manual and calibration certificate

22 of 81