EC&M Variable Frequency Crane Control (ENDEAVOR)
ENDEAVOR TM VARIABLE FREQUENCY CRANE CONTROL
FEBRUARY, 2008
CLASS
DRIVE SYSTEM SELECTION
DRIVE SELECTION TABLES
Drive Current Rating at 50°C Altitude <1000m
Drive Current Rating at 50°C Altitude <1000m
TYPE Code ▀ (460V code shown)
Nominal HP
TYPE Code ▀ (460V code shown)
Nominal HP
SPA4
1
2.1
SPN4
60
68
SPB4
2
3.0
SPP4
75
86
SPC4
3
5.8
SPR4
100
113
SPD4
5
9.5
SPS4
125
140
SPF4 SPH4
7.5 - 10 15 - 20
15.5 22.3
SPT4 SPU4
150 200
210
SPJ4
25
32
SPV4
250
Consult Factory
SPK4 SPM4
30
46 60
SPW4 SPX4
300
40-50 350 Example: Motor Full Load Current (FLC) must be less than Drive Current Rating. To select a drive system for a 65A FLC motor (nominal 50HP at 460VAC), NEMA 12 enclosed, travel motion, simplex, with 5-speed interface, inverter-duty rated squirrel cage motor, the selection is: Class 6417 Type SPN4ATS5S (60HP nominal drive). ▀ For 380VAC systems, change type number vol tage code from 4 to 3, e.g. 6417 Type SPN 4 ATS5S becomes 6417 Type SPN 3 ATS5S
Drive Current Rating at 50°C Altitude <1000m
Drive Current Rating at 50°C Altitude <1000m
TYPE Code (230V code shown)
Nominal HP
Nominal HP
TYPE Code
SPA2 SPB2 SPC2 SPD2 SPE2
1 2 3 5
4.3 7.5
SPF2 SPG2 SPH2 SPJ2 SPK2
10 15 20 25 30
31
42.0 56.0 68.0 80.0
12.6 17.0 19.2
7.5
Drive Current Rating at 50°C Altitude <1000m
Drive Current Rating at 50°C Altitude <1000m
TYPE Code (575V code shown)
Nominal HP
Nominal HP
TYPE Code
SPB5 SPC5 SPD5 SPE5 SPF5 SPG5 SPH5 SPJ5 SPK5 SPL5
SPM5 SPN5 SPP5 SPR5 SPS5 SPT5 SPU5 SPV5 SPW5 SPX5
1 - 2
4.1 5.4 6.1 9.5
50 60 75
51.9
3 5
63 84
7.5
100 125 150 200 250 300 350
100 125
10 15 20 25 30 40
12.0 18.0 22.0 27.0 36.0 43.0
Consult Factory
DUPLEX (TWO MOTORS PER EACH DRIVE) AND MULTI-INVERTER DUPLEX (ONE DRIVE PER MOTOR) SYSTEM RATINGS AVAILABLE – CONSULT FACTORY FOR DETAILS
4
Made with FlippingBook flipbook maker