Compression Terminals (DF) - Distribution Connectors
VERSAtile™ ALUMINUM COMPRESSION TERMINAL TYPE VACL
ALUMINUM VACL
• For use with either VERSA-CRIMP ® or conventional compression tools. • UL listed for aluminum or copper conductors. • Factory inhibited • Color coded end plugs for easy die selection (see page DF-16 and DF-17).
D
L
Material:
Body - Aluminum Alloy-Tin Plated
T
LISTED 261L
W
AL9CU (90° RATED)
Product Data & Conductor Size
ALUMINUM OR COPPER CONDUCTOR
DIMENSIONS INCHES (MM)
VERSA- CRIMP
APPROX. WT. EACH LBS. (KG)
NO. PAD HOLES
PAD BOLT DIA.
I.D. INCHES (MM)
CATALOG NUMBER
CONVENTIONAL TOOLING RANGE
VERSA-CRIMP® SYSTEM RANGE
TOOL TYPE
L
D W T
2-5/16 (58.7) 2-5/16 (58.7) 2-1/2 (63.5) 2-1/2 (63.5) 2-1/2 (63.5) 2-3/4 (69.9) 2-3/4 (69.9) 2-15/16 (74.6) 3-1/8 (79.4) 4-7/8 (128.8) 2-15/16 (74.6) 3-1/8 (79.4) 4-7/8 (128.8)
1 (25.4) 1 (25.4) 1-1/8 (28.4) 1-1/8 (28.4) 1-1/8 (28.4) 1-1/8 (28.4) 1-1/8 (28.4) 1-5/16 (33.3) 1-5/16 (33.3) 1-5/16 (33.3) 1-5/16 (33.3) 1-5/16 (33.3) 1-5/16 (33.3)
13/16 (20.6) 13/16 (20.6) 7/8 (22.2) 7/8 (22.2) 7/8 (22.2) 3/4 (19.0) 3/4 (19.0) 13/16 (20.6) 13/16 (20.6) 13/16 (20.6) 15/16 (23.8) 15/16 (23.8) 15/16 (23.8)
1/8 (3.2) 1/8 (3.2) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 3/16 (4.8) 1/4 (6.3) 1/4 (6.3) 1/4 (6.3)
.02 (.01) .02 (.01) .04 (.02) .04 (.02) .04 (.02) .05 (.02) .05 (.02) .05 (.02) .05 (.02) .05 (.02) .07 (.03) .07 (.03) .12 (.05)
.252 (6.4) .252 (6.4) .312 (7.9) .312 (7.9) .312 (7.9) .350 (8.9) .350 (8.9) .393 (10.0) .393 (10.0) .393 (10.0) .450 (11.4) .450 (11.4) .450 (11.4)
VACL414
1
1/4
#4 Str. Al/Cu
#4 Str. Al/Cu VC6350
VACL438
1
3/8
VACL214
1
1/4
DF 2
VACL2516 1
#2 Str. Al/Cu #6—#2 Str. Al/Cu
5/16
VACL238
1
3/8
VACL1516
1
5/16
#1 Str. Al/Cu #4—#1 Str. Al/Cu
VACL138
1
3/8
VC6 (ALL)
VACL1038 1
3/8
VACL1012
1
1/0 Str. Al/Cu #8—1/0 Str. Al/Cu
1/2
VACL1012BN 2
1/2
VACL2038 1
3/8
VACL2012
1
2/0 Str. Al/Cu #4—2/0 Str. Al/Cu
1/2
VACL2012BN 2
1/2
Continued on next page.
HIGH VOLTAGE APPLICATIONS—All Aluminum/Copper and Copper Lugs (VCEL, VACL, VHCL, VHCS and VCELC) are rated at 34.5KV. The other U.L. Listed com- pression connectors (VACS, VACT, VCCT, VHSS and VHS) have a maximum UL voltage requirement of less than 2000 volts, however Anderson recommends these connectors for application through 34.5 KV subject to manufacturers’ limitations for insulation material.
ANDERSON ™
HUBBELL ® POWER SYSTEMS
FARGO ®
December 2014
Made with FlippingBook - professional solution for displaying marketing and sales documents online