Chance Technical Design Manual
GRADE BEAM
SUPPORT TOP OF WALL WITH ADEQUATE ANCHOR BOLTS AND FRAMING
SEE TABLE FOR TOP & BOTTOM REINFORCING (SPLICE TOP AT MID-SPAN OF PILES; SPLICE BOTTOM OVER PILE)
HEIGHT (SEE TABLE)
SEE TABLE FOR STIRRUPS (VERT. REINFORCEMENT)
3” COVER (TYP.)
12”
CHANCE® HELICAL PILE
GRADE BEAM REINFORCING STEEL CONFIGURATION (SEE TABLE 4-14) FIGURE 4-15
GRADE BEAM REINFORCING STEEL CONFIGURATION, TABLE 4-14
TOTAL FOUNDATION LINE LOAD
LOAD DETERMINATION
2,000 (lb/ft)
3,000 (lb/ft)
4,000 (lb/ft)
PILE SPACING
STEEL REINFORCING BARS REQUIRED
TOP & BOTTOM
STIRRUPS (O.C.)
TOP & BOTTOM
STIRRUPS (O.C.)
TOP & BOTTOM
STIRRUPS (O.C.)
HEIGHT
HEIGHT
HEIGHT
8’
18” 18” 24” 24”
2 - #5 #3 @ 12” 3 - #5 #3 @ 12” 3 - #5 #3 @ 12” 4 - #5 #3 @ 12”
20” 22” 27” 30”
3 - #5 #3 @ 12” 3 - #5 #3 @ 12” 4 - #5 #3 @ 15” 4 - #5 #3 @ 15”
24” 30” 30” 36”
4 - #5 #3 @ 12” 4 - #5 #3 @ 15” 4 - #5 #3 @ 15” 4 - #6 #3 @ 18”
10’ 12’ 15’
Page 4-18 | Hubbell Power Systems, Inc. | All Rights Reserved | Copyright © 2023