Chance Technical Design Manual

GARDEN LEVEL WALL

SUPPORT TOP OF WALL WITH ADEQUATE ANCHOR BOLTS AND FRAMING

SEE TABLE FOR TOP & BOTTOM REINFORCING (SPLICE TOP AT MID-SPAN OF PILES; SPLICE BOTTOM OVER PILE)

#4 @ 20” EACH FACE AS REQ.

BACKFILL

3’ TO 5’ BELOW GRADE

SEE TABLE FOR STIRRUPS (VERT. REINFORCEMENT)

10” MIN

FROST DEPTH +6” (MIN)

4” MIN

PERIMETER DRAIN

16” MIN

10”

4” VOID FORM UNDER FOOTING (EXPANSIVE SOILS ONLY)

CHANCE® HELICAL PILE

GARDEN LEVEL WALL REINFORCING STEEL CONFIGURATION (SEE TABLE 4-11) FIGURE 4-12

18”

GARDEN LEVEL WALL REINFORCING STEEL CONFIGURATION, TABLE 4-11

TOTAL FOUNDATION LINE LOAD

3,000 (lb/ft)

4,000 (lb/ft)

5,000 (lb/ft)

6,000 (lb/ft)

7,000 (lb/ft)

PILE SPACING

WALL HEIGHT

STEEL REINFORCING BARS REQUIRED

TOP & BOTTOM

STIRRUP (O.C.)

TOP & BOTTOM

STIRRUP (O.C.)

TOP & BOTTOM

STIRRUP (O.C.)

TOP & BOTTOM

STIRRUP (O.C.)

TOP & BOTTOM

STIRRUP (O.C.)

LOAD DETERMINATION

3’ 4’

2 - #5 2 - #4

2 - #6 2 - #5

2 - #6 2 - #6

2 - #7 2 - #6

2 - #7 2 - #7

#3 @ 15”

#3 @ 15”

#3 @ 15”

#3 @ 15”

#3 @ 15”

8’

5’ 2 - #4 #3 @ 12” 2 - #4 #3 @ 12” 2 - #5 #3 @ 12” 2 - #5 #3 @ 12” 2 - #6 #3 @ 12”

3’ 4’

2 - #6 2 - #5

2 - #7 2 - #6

2 - #7 2 - #7

2 - #8 2 - #8

2 - #8 2 - #8

#3 @ 15”

#3 @ 15”

#3 @ 15”

#3 @ 15”

#3 @ 15”

10’

5’ 2 - #5 #3 @ 12” 2 - #6 #3 @ 12” 2 - #6 #3 @ 12” 2 - #7 #3 @ 12” 2 - #7 #3 @ 12”

3’ 4’

2 - #7 2 - #6

2 - #7 2 - #7

2 - #8 2 - #8

4 - #6 2 - #8

4 - #7 2 - #8

#3 @ 15”

#3 @ 15”

#3 @ 15”

#3 @ 15”

#3 @ 15”

12’

5’ 2 - #6 #3 @ 12” 2 - #7 #3 @ 12” 2 - #7 #3 @ 12” 2 - #8 #3 @ 12” 4 - #6 #3 @ 12”

4 - #7 4 - #6

4 - #8 #3 @ 10” 5 - #8 #3 @ 9” 4 - #7 #3 @ 15” 4 - #8 #3 @ 15”

3’ 4’

2 - #8 2 - #8

4 - #6 2 - #8

#3 @ 15”

#3 @ 15”

#3 @ 15”

15’

5’ 2 - #7 #3 @ 12” 2 - #8 #3 @ 12” 4 - #7 #3 @ 12” 4 - #7 #3 @ 12” 4 - #7 #3 @ 12”

Page 4-14 | Hubbell Power Systems, Inc. | All Rights Reserved | Copyright © 2023

Made with FlippingBook - professional solution for displaying marketing and sales documents online