Chance Technical Design Manual
Design Steps Atlas Resistance ® Piers
Owner, Prime Contractor or Consultant Requires Remedial Deep Foundation Design
NO
YES
Determine Structural Loads (See Section 4)
Structural Loading Available
Review by CHANCE® Helical Pile/Anchor Designer, CHANCE® Distributor, and/or Certified CHANCE® Installer
Geotechnical Report
PRODUCT FEASIBILITY
NO
YES
Feasibility Assessment
Select Pier Type (See Section 7)
Determine Pier Spacing and Select Shaft Size
• Based on Load • Based on Analysis of Strength of Footing • Based on Ultimate Strength of Suitable Piers
Calculation of Pier Strength Requirements
Lateral Load Buckling
Corrosion
Installation Criteria and Report
Specification and Shop Drawings (as required)
DESIGN FLOWCHART FOR ATLAS RESISTANCE ® PIERS (REMEDIAL REPAIR APPLICATIONS), FIGURE 3-3
Hubbell Power Systems, Inc. | All Rights Reserved | Copyright © 2023 | Page 3-7