Chance Technical Design Manual

NOMINAL, LRFD DESIGN, & ASD ALLOWABLE STRENGTHS OF NEW CONSTRUCTION PILE CAPS LOADED IN TENSION 1,2,3,4,5,6,7,8

DRAWINGS & RATINGS

NOMINAL, LRFD DESIGN, & ASD ALLOWABLE STRENGTHS IN TENSION (kip) [kN] 2500 psi CONCRETE 5 3000 psi CONCRETE 5 4000 psi CONCRETE 5 NOMINAL STRENGTH DESIGN STRENGTH ALLOWABLE STRENGTH NOMINAL STRENGTH DESIGN STRENGTH ALLOWABLE STRENGTH NOMINAL STRENGTH DESIGN STRENGTH ALLOWABLE STRENGTH

CATALOG NUMBER 8

PILE MODEL

56.2 [250] 78.9 [351] 95.0 [422] 100 [444] 87 [387]

42.1 [187] 59.2 [263] 70.4 [313] 76.9 [342]

28.1 [125] 39.5 [176] 47.5 [211] 51.9 [231]

56.2 [250] 78.9 [351] 95.0 [422] 100 [444] 87 [387]

42.1 [187] 59.2 [263] 71.3 [317] 77.9 [346]

28.1 [125] 39.5 [176] 47.5 [211] 51.9 [231]

56.2 [250] 78.9 [351] 95.0 [422] 100 [444] 87 [387]

42.1 [187] 59.2 [263] 71.3 [317] 77.9 [346]

28.1 [125] 39.5 [176] 47.5 [211] 51.9 [231]

C1500465(G)

SS5

C1500467(G)

SS175

C150797(G) RS2875.276

C1501357(G) RS3500.300

65.3 [290.5] 105.7 [470.2] 33.9 [150.8] 45.6 [202.8]

43.5 [193.5] 70.5 [313.6] 22.6 [100.5] 30.4 [135.2]

65.3 [290.5] 105.7 [470.2] 33.9 [150.8] 45.6 [202.8]

43.5 [193.5] 70.5 [313.6] 22.6 [100.5] 30.4 [135.2]

65.3 [290.5] 105.7 [470.2] 33.9 [150.8] 45.6 [202.8]

43.5 [193.5] 70.5 [313.6] 22.6 [100.5]

C1500797(G) RS2875.203

140.9 [626.8] 45.2 [201.1] 60.8 [270.5]

140.9 [626.8] 45.2 [201.1] 60.8 [270.5]

140.9 [626.8] 45.2 [201.1] 60.8 [270.5]

C1072727(G) RS4500.337

C1500793(G)

SS5

30.4 135.2]

C1500794(G)

SS175

Notes: For SI: 1 inch = 25.4 mm, 1 kip = 4.448 kN.

1 Refer to Section 4.1.3 of ICC-ES ESR-2794 for descriptions of fixed condition, pinned condition, soft soil, and firm soil. 2 Strength ratings include allowance for corrosion of zinc-coated new construction pile caps over a 50-year service life. 3 Capacities apply to the specific pile cap and pile models listed. 4 See Sections 4.1.2 and 5.7 of ICC-ES ESR-2794 for applicable limit states that must be evaluated by a registered design professional. 5 The specified compressive strength of concrete at 28 days must not be less than 2,500 psi (17.2 MPa) [minimum of 24 MPa is required under ADIBC Appendix L, Section 5.5.1]. 6 Anchorage design must comply with the requirements of Section 1810.3.11.2 of the IBC for Seismic Design Categories D, E, and F. 7 The concrete footing design, reinforcement design, and anchorage capacity between the bracket and concrete must be determined by a registered design professional. The bracket anchorage with concrete may control the capacity. 8 (G): The cap is available as galvanized and nongalvanized (bare steel). Catalog items with “G” suffix are galvanized and without “G” are bare steel.