Chance Technical Design Manual
NOMINAL, LRFD DESIGN, & ASD ALLOWABLE STRENGTHS OF NEW CONSTRUCTION PILE CAPS LOADED IN TENSION 1,2,3,4,5,6,7,8
DRAWINGS & RATINGS
NOMINAL, LRFD DESIGN, & ASD ALLOWABLE STRENGTHS IN TENSION (kip) [kN] 2500 psi CONCRETE 5
CATALOG NUMBER 8
PILE MODEL
NOMINAL STRENGTH
DESIGN STRENGTH
ALLOWABLE STRENGTH
C1500465(G)
SS5
56.2 [250]
42.1 [187]
28.1 [125]
C1500793(G)
SS5
45.2 [201.1]
33.9 [150.8]
22.6 [100.5]
C1500467(G)
SS175
78.9 [351]
59.2 [263]
39.5 [176]
C1500794(G)
SS175
60.8 [270.5]
45.6 [202.8]
30.4 [135.2]
C1500797(G)
RS2875.203
100 [444.8]
76.9 [290.5]
51.9 [193.5]
C1500797(G)
RS2875.276
87.0 [387]
65.3 [313]
43.5 [211]
C1501357(G)
RS3500.300
95.0 [422.6]
70.4 [342]
47.5 [231]
C1072727(G)
RS4500.337
140.9 [626.8]
105.7 [470.2]
70.5 [313.6]
Notes: For SI: 1 inch = 25.4 mm, 1 kip = 4.448 kN. 1 Refer to Section 4.1.3 of ICC-ES ESR-2794 for descriptions of fixed condition, pinned condition, soft soil, and firm soil.
2 Strength ratings include allowance for corrosion of zinc-coated new construction pile caps over a 50-year service life. The 50-year service life allow ance for non-galvanized (bare steel) new construction pile caps used with SS5 and SS175 helical piles results in tension strengths equal to 90% of the strength values of galvanized pile caps listed in the Table. 3 Capacities apply to the specific pile cap and pile models listed. 4 See Sections 4.1.2 and 5.7 of ICC-ES ESR-2794 for applicable limit states that must be evaluated by a registered design professional. 5 The specified compressive strength of concrete at 28 days must not be less than 2,500 psi (17.2 MPa) [minimum of 24 MPa is required under ADIBC Appendix L, Section 5.5.1]. 6 Anchorage design must comply with the requirements of Section 1810.3.11.2 of the IBC for Seismic Design Categories D, E, and F. 7 The concrete footing design, reinforcement design, and anchorage capacity between the bracket and concrete must be determined by a registered design professional. The bracket anchorage with concrete may control the capacity. 8 (G): The cap is available as galvanized and non-galvanized (bare steel). Catalog items with “G” suffix are galvanized and without “G” are bare steel.
Hubbell Power Systems, Inc. | All Rights Reserved | Copyright © 2026 | Page 7-95
Made with FlippingBook - professional solution for displaying marketing and sales documents online