CanadianConnectors (CA05041E )
Conductor Protection— Protector Rods Primary application as a mechanical reinforcement layer for mounting dampers or other devices on ACSS conductors or OPGW cables where suspension support reinforcing rods are not available to mount damper or device. For EHV applications, add suffix “E” to catalog numbers to Specify. Example PR5158E
ALUMINUM PR5
Product Data and Conductor Size
Conductor / OPGW Dia. Range In. (mm)
Nominal Conductor Size (AWG or KCMIL)
Applied Length (in.)
Rod Dia. (in.)
Rods Per Set
Sets Per Carton
Wt. Per Carton (lbs.)
Color Code
Catalog Number
Min. 0.476 (12.1) 0.534 (13.6) 0.586 (14.9) 0.619 (15.7) 0.668 (17.0) 0.723 (18.4) 0.817 (20.8) 0.899 (22.8) 0.955 (24.3) 1.020 (25.9) 1.065 (27.1) 1.099 (27.9) 1.299 (33.0) 1.416 (36.0) 1.544 (39.2) 1.686 (42.8) 1.182 (30.0)
Max. 0.533 (13.5) 0.585 (14.9) 0.618 (15.7) 0.667 (16.9) 0.722 (18.3) 0.816 (20.7) 0.898 (22.8) 0.954 (24.2) 1.019 (25.9) 1.064 (27.0) 1.098 (27.9) 1.181 (30.0) 1.415 (35.9) 1.543 (39.2) 1.685 (42.8) 1.84 (46.7) 1.298 (33.0)
ACSS
ACSS/TW
PR5139
16
0.121
13
50
14
Blue
PR5141
16
0.121
14
50
14
Green
PR5142
16
0.146
13
50
21
Orange
PR5144
266.8 (26/7) (30/7)
16
0.146
14
50
21
Purple
PR5146
336.4 (26/7)
336.4 (17/7) T23
20
0.146
15
50
29
Red
477 (18/7) T13 477 (18/7) T16 477 (16/7) T23 556.5 (20/7) T16
PR5148
397.5 (26/7) (30/7)
20
0.146
16
50
29
Black
PR5150
477 (26/7) (30/7)
20
0.146
18
50
31
White
PR5151
556.5 (26/7) (30/7)
636 (20/7) T16
24
0.167
17
50
47
Yellow
636 (24/7) (26/7) (30/19) 666 (24/7) (26/7)
795 (21/7) T13 795 (20/7) T16 795 (22/19) T23 954 (33/7) T7
PR5152
24
0.182
17
25
29
Brown
715 (24/7) (26/7) 795 (45/7)
PR5154
24
0.182
18
25
29
Blue
PR5155
795 (24/7) (54/7)
954 (21/7) T13
26
0.204
17
25
36
Green
1033.5 (33/7) T7 1033.5 (21/7) T13 1113 (33/7) T7
795 (26/7) (30/19) 954 (45/7) 954 (54/7) (30/19) 1033.5 (45/7) (54/7) 1113 (45/7) (54/19) 1192.5 (45/7) (54/19) 1272 (45/7) (54/19) 1351.5 (45/7) 1351.5 (54/19) 1431 (45/7) (54/19) 1590 (45/7
PR5156
26
0.250
14
25
48
Orange
1113 (39/19) T13 1192.5 (39/19) T13 1272 (33/7) T7 (39/19) T13 1351.5 (33/7) T7
PR5158
26
0.250
15
25
51
Purple
1351.5 (39/19) T13 1590 (36/7) T7 1590 (42/19) T13 1780 (38/19) T8
PR5160
26
0.250
17
20
44
Blue
PR5162
26
0.250
18
20
48
Yellow
1590 (54/19) 1780 (84/19)
PR5163
2156 (64/19) T8
26
0.250
19
15
40
Brown
PR5164
2156 (84/19)
26
0.250
21
15
42
Blue
NOTES: (1) Right-hand lay standard. (2) For conductor/cable sizes not listed above, select rod set based on cable dia. range. (3) Applied O.D. of conductor/cable with rods equals cable diameter plus two times rod diameter. (4) Maximum conductor temperature limits vary with suspension clamp designs. Consult factory for information.
©2017 Hubbell Incorporated | hubbellpowersystems.com
G-12