CHANCE Lineman Grade Tools & Grounding Catalog (Combined)

Jumper Cable rated Ø-Ø 15 kV with EPR Insulation/Jacket Features & Applications • Extremely flexible even at low temperatures • Features insulation/jacket combination resistant to abrasion, oil, heat, moisture and ozone • Orange/Red color of mold-cured ethylene-propylene-base coating imparts high visibility • AWG size and voltage rating are embossed at 4-foot intervals for easy identification • For extended service life, an extruded screen interfaces insulation and conductor • This strand screen improves voltage-stress control by adding dielectric strength and eliminating internal corona • Insulation and conductor screen meet and exceed ICEA-NEMA standard S-68-516 • For easy handling in adverse conditions, conductors are extra flexible alloy-coated copper-stranded rope per ASTM B-189 or B-33 • Ampacity ratings are based on 90°C conductor temperature at 40°C ambient Type I per ASTM F 2321 Standard Specification

Approx. Cond. Diameter

Approx. Cable O.D.

Approx. Ampacity Rating, Amps

Weight Per 1000 Ft.

Size AWG #2

Catalog No. S10043 S10044 S10045 S10046

Stranding 259/No. 26 413/No. 24 273/No. 23 437/No. 21

1/0 2/0 4/0 0.322" 0.404" 0.455" 0.602" Jumper Cable rated Ø-Ø 25 kV and 35 kV with EPR Insulation/Jacket Features & Applications • Extremely flexible even at low temperatures • Features insulation/jacket combination resistant to abrasion, oil, heat, moisture and ozone • Orange/Red color of mold-cured ethylene-propylene-base coating imparts high visibility • AWG size and voltage rating are embossed at 4-foot intervals for easy identification • For extended service life, an extruded screen interfaces insulation and conductor • This strand screen improves voltage-stress control by adding dielectric strength and eliminating internal corona • Insulation and conductor screen meet and exceed ICEA-NEMA standard S-68-516 • For easy handling in adverse conditions, conductors are extra flexible alloy-coated copper-stranded rope per ASTM B-189 or B-33 • Ampacity ratings are based on 90°C conductor temperature at 40°C ambient 438 lb./197 kg. 598 lb./269 kg. 707 lb./318 kg. 1047 lb./471 kg. 200 260 300 400 0.779" 0.863" 0.914" 1.065"

Jumpers & Load Pi ckup Tool s – 2300

For connectors, see page 2304.

Type I per ASTM F 2321 Standard Specification

Approx. Cond. Diameter

Approx. Cable O.D.

Approx. Ampacity Rating, Amps

Weight Per 1000 ft.

Size AWG

Stranding

Catalog No.

25 kV Cable: S11272 S11273

1/0 2/0

413 266

0.404" 0.450"

1.113" 1.160"

260 300

801 lb./ 360.5 kg. 913 lb./410.9 kg.

Type I per ASTM F 2321 Standard Specification

35 kV Cable: S11274

1/0

413

0.404"

1.287"

260

985 lb./443.3 kg.