Insulators Catalog - Full Catalog (CA08051E)
Section Length
Section Length
Suspension Insulators Mechanical Ratings SML = 120 kN RTL = 60 kN 5/8” (16 mm) Rod Diameter
Type
xmm (in.)
ymm (in.)
x
A10..
97 (3.8)
114 (4.5)
D10..
109 (4.3)
140 (5.5)
Standard Design 94 mm (3.7")
G10..
130 (5.1)
160 (6.3)
High Leak Design y
(2) IEC Wet Switching Impulse Withstand (ANSI 60 Hz. Dry F.O.) kV
(2) IEC Lightning Impulse Withstand (ANSI Critical Impulse F.O.) kV
(2) IEC Power Freq. Wet Withstand (ANSI 60 Hz. Wet F.O.) kV
Selection Guide Typical Line Voltage, kV (1)
Leakage Distance mm (in.) XX =
Catalog Number with ANSI 52-5 ball and Y-Clevis
Dry Arc Distance mm (in.)
Section Length mm (in.)
No.of Sheds
70 110 132 161 220 330 400 51
A1
D1
G1
Pos-kV Neg-kV
1160 (45) 1550 (61) 1940 (76) 2320 (91) 2710 (107) 3100 (122) 3490 (137) 3880 (152) 4270 (168) 4660 (183) 5040 (198) 5430 (214) 5820 (229) 6210 (244) 6600 (260) 6990 (275) 7380 (290) 7770 (306) 8150 (321) 8540 (336) 8930 (351)
1340 (53) 1790 (70) 2230 (88) 2680 (105) 3130 (122) 3580 (141) 4020 (158) 4480 (176) 4930 (194) 5370 (211) 5820 (229) 6270 (247) 6720 (264) 7170 (282) 7610 (299) 8060 (317) 8510 (335) 8960 (353) 9400 (370) 9860 (388) 10310 (406)
1530 (60) 2040 (80) 2540 (100) 3060 (120) 3570 (140) 4080 (160) 4580 (180) 5100 (200) 5610 (221) 6120 (241) 6620 (261) 7140 (281) 7650 (301) 8160 (321) 8670 (341) 9180 (361) 9700 (381) 10210 (402) 10710 (421) 11220 (442) 11740 (462)
1760 (69) 2350 (92) 2920 (115) 3520 (138) 4110 (162) 4700 (185) 5280 (207) 5870 (231) 6460 (254) 7050 (277) 7630 (300) 8220 (323) 8810 (347) 9400 (370) 9980 (393) 10570 (416) 11170 (439) 11760 (463) 12330 (485) 12930 (509) 13520 (532)
725
470
260
135
275
255
XX00032A07
12
(28.6)
(18.5)
(180)
(180)
(310)
(285)
881
625
345
180
365
350
XX00042A07
16
(34.7)
(24.6)
(245)
(240)
(410)
(390)
1033
775
420
220
450
440
XX00052A07
20
(40.7)
(30.6)
(310)
(295)
(505)
(490)
1189
930
500
260
540
530
XX00062A07
24
(46.8)
(36.8)
(370)
(350)
(605)
(595)
1345
1090
570
305
630
620
XX00072A07
28
(53.0)
(42.9)
(430)
(405)
(700)
(695)
1501
1245
650
340
715
710
XX00082A07
32
(59.1)
(49.0)
(490)
(455)
(795)
(795)
1654
1395
720
380
800
800
XX00092A07
36
(65.1)
(55.0)
(545)
(505)
(890)
(890)
1810
1555
790
420
885
890
XX00102A07
40
(71.3)
(61.2)
(600)
(555)
(985)
(990)
1966
1710
860
455
970
975
XX00112A07
44
(77.4)
(67.3)
(655)
(605)
(1080)
(1090)
2121
1865
930
490
1050
1065
XX00122A07
48
(83.5)
(73.5)
(710)
(655)
(1170)
(1185)
2274
2015
995
525
1135
1145
XX00132A07
52
(89.5)
(79.5)
(760) 1060 (810) 1120 (855) 1185 (905) 1240 (945) 1300 (990) 1355
(700)
(1260)
(1280)
2430
2175
560
1215
1230
XX00142A07
56
(95.7)
(85.6)
(750)
(1350)
(1370)
2586
2330
595
1295
1315
XX00152A07
60
(101.8)
(91.7)
(790)
(1440)
(1465)
2742
2485
625
1375
1400
XX00162A07
64
(108.0)
(97.9)
(835)
(1530)
(1560)
2894
2635
655
1455
1480
XX00172A07
68
(114.0)
(103.9)
(880)
(1615)
(1650)
3050
2795
690
1530
1565
XX00182A07
72
(120.1)
(110.0)
(920)
(1705)
(1740)
3206
2950
720
1610
1645
XX00192A07
76
(126.2)
(116.2)
(1030)
(960)
(1790)
(1830)
3362
3105
1410
745
1685
1725
XX00202A07
80
(132.4)
(122.3)
(1070)
(1000)
(1875)
(1920)
3514
3260
1460
775
1760
1800
XX00212A07
84
(138.4)
(128.3)
(1110)
(1040)
(1960)
(2005)
HI*LITE
3670
3415
1510
800
1835
1880
XX00222A07
88
(144.5)
(134.4)
(1145)
(1075)
(2040)
(2090)
3826
3570
1560
830
1910
1955
XX00232A07
92
(150.7)
(140.6)
(1180)
(1110)
(2125)
(2175)
Notes: 1. For voltages above 400 kV, and other section lengths, contact your HPS representative. 2. Electrical values are without corona ring. For voltages equal to or greater than 161 kV, refer to the dedicated page within this section for corona rings and associated physical/electrical changes to the above data.
Length Change
Ground Fitting
Line Fitting
Suffix Code
Inches
mm
Eye
Eye
2000
+2.3
+59
Eye
IEC 16 mm Ball
2007
+1.0
+26
Y-Clevis
IEC 16 mm Ball
2207
+0.9
+24
Y-Clevis
Eye
2200
+2.2
+57
IEC 16C Clevis
Eye
2800
+1.2
+31
Page 5-73 | January 2019