Bonding and Grounding - Communication (CA12005E)

U-Shaped BSWShield Connectors

BARP SERIES – SPARK GAP SHIELD TERMINATION

Description These clamps are designed for use in the distribution pedestal where an indirect or isolated type of connection is desired. This method of termination prevents the shield of the buried service wire from becoming a conductor of unwanted stray voltages, yet allowing higher voltages, such as lightning, to go safely to ground. Applications Works with 2 pair–6 pair shielded buried service wire if the jacket can be stripped from the shield.Works with all of the major pedestals. Features • The spark gap is built into the clamp itself, eliminating the craft-sensitive methods of termination, such as a circumferential knife cut in the jacket, or a buildup of electrical tape. • Available with an insulator boot. • Minimum spark-over voltage is 1–3 KV. • Meets Bellcore criteria for lightning surge per spec #TR-NWT-001001. • Spark gap electrodes can be easily bypassed, if desired, by tightening the side screw in the insulator. This bridges across the electrodes, making a direct connection to ground.

air gap insulator

attach to ground point in pedestal

Make no adjustments to this screw for proper spark gap (less than 500-ft. runs)

BONDING &

GROUNDING

*Side screw in for direct connection (500-ft. runs or longer)

Loosen side screw, rotate plastic collar to the larger portion of the slot, and re-tighten.

See next page for ordering information.