BURNDY Master Catalog (20190422)
Compression Grounding
HYGROUND ® Compression System HYTAP™ Type YGHHC-C Double Figure C Connector
HYTAP™ Type YGHHC-C Double Figure C Connector
IEEE-837 2014 Qualified!
Irreversible compression ground tap figure “C” connectors. Accommodates all cable combinations from #6 solid through 500 kcmil. “C”- shaped opening permits placing two continuous parallel cables into conductor groove. The YGHHC-C series is qualified to IEEE-837 2014. Prefilled with PENETROX™compound and strip sealed.
Commercial Copper Cable toCable or Cable toGroundRod
InstallationData
StrandedCopper CableRangeMetric
Die Index No.
No. of Crimps
Catalog Number
H L Z
Y750/Y35/ PAT750/Y39
Y45
Y46
Run
Tap
Run
Tap
3
4
35mm² (7.62mm) 70mm² (10.9mm) 95mm² (12.5mm) 120mm² (14.4mm) 95mm² (12.5mm) 120mm² (14.4mm) 150mm² (16mm) 240mm² (20.35mm) 150mm² (16mm) 240mm² (20.35mm) 150mm² (16mm) 240mm² (20.35mm)
35mm² (7.62mm) 70mm² (10.9mm) 10mm² (4.10mm) 70mm² (10.90mm) 95mm² (12.5mm) 120mm² (14.4mm) 10mm² (4.10mm) 70mm² (10.90mm) 95mm² (12.5mm) 120mm² (14.4mm) 150mm² (16mm) 240mm² (20.35mm)
1 Str. (0.328) 2/0 Str. (0.419) 3/8" Rod
1 Str. (0.328) 2/0 Str. (0.419)
1.54 [39]
0.75 [19]
1.88 [48]
YGHHC26C26
O U-O U-O U-O 2
3/0 Str. (0.470) 250 kcmil (0.575) 1/2" or 5/8" Rod 3/0 Str. (0.470) 250 kcmil (0.575) 1/2" or 5/8" Rod 300 kcmil (0.630) 500 kcmil (0.813) 3/4" Rod
6 Sol. (0.162) 2/0 Str. (0.419)
1.97 [50]
0.88 [22]
2.13 [54]
YGHHC29C26
997
U997
U997
U997
2
3/0 Str. (0.470) 250 kcmil (0.575)
2.06 [52]
0.88 [22]
2.13 [54]
YGHHC29C29
997
U997
U997
U997
2
6 Sol. (0.162) 2/0 Str. (0.419)
2.42 [62]
0.88 [22]
2.13 [54] 1011 U1011
YGHHC34C26
S1011 P1011
4
6
YGHHC34C29 6
300 kcmil (0.630) 500 kcmil (0.813)
3/0 Str. (0.470) 250 kcmil (0.575)
2.67 [68]
0.88 [22]
2.13 [54] 1011 U1011
S1011 P1011
4
YGHHC34C34 300 kcmil (0.630) 500 kcmil (0.813)
300 kcmil (0.630) 500 kcmil (0.813)
2.91 [74]
1.10 [28]
2.58 [66] 1011 U1011
S1011 P1011
6
6
For ground rod to wire applications, ground rod must be precrimped; see table for appropriate precrimp dies Where a “U” or “PU” die is recommended with the Y45 HYPRESS™, a PT6515 adapter must be used Where a “U” or “PU” die is recommended with the Y46 HYPRESS™, a PUADP-1 adapter must be used
These connectors cannot be installed with the Y35 or Y39 HYPRESS™
2
6
Ground Rod Dia.
PRECRIMP Dies
3
UPRECRIMP 12 UPRECRIMP 58 UPRECRIMP 34
1/2" 5/8" 3/4"
4
U2CABT
1-800-387-6487 (Canada) 1-603-647-5299 (International)
E-11
Made with FlippingBook - Online Brochure Maker