Acme - Section 4 - Drive Isolation & AC Line Reactors (AE_CAT_4_001)

Dr i ve Isolat ion and AC Line Reactors

S e c t i o n 4 | W i r i n g D i a g r a m s PRIMARY: 460 Volts Delta

PRIMARY: 575 Volts Delta SECONDARY: 230Y/133 Volts TAPS: 1-5% ANFC and BNFC

PRIMARY: 575 Volts Delta SECONDARY: 460Y/266 Volts TAPS: 2-2 1/2% ANFC and BNFC

SECONDARY: 460Y/266 Volts TAPS: 1-5% ANFC and BNFC

Primary Volts % Connect Leads to Tap No. 483 105 1 460 100 2 437 95 3 Secondary Volts 460 X1, X2, X3 266 X1 & X0, X2 & X0 1 phase X3 & X0

Primary Volts

Connect Leads to Tap No.

Primary

Connect Leads

%

Volts

%

to Tap No.

604 589 575 561 546

105

1 2 3 4 5

604 575 546

105 100

1 2 3

102.5

100 97.5

95

Secondary Volts 230

95

Secondary Volts 460

X1, X2, X3

PRIMARY: 460 Volts Delta SECONDARY: 460Y/266 Volts TAPS: 2-2 1/2% ANFC and BNFC

X1, X2, X3

X1 & X0 X2 & X0 X3 & X0

133

X1 & X0 X2 & X0 X3 & X0

1 phase

266 1 phase

PRIMARY: 575 Volts Delta SECONDARY: 230Y/133 Volts TAPS: 2-2 1/2% ANFC and BNFC

PRIMARY: 230 Volts Delta SECONDARY: 230Y/133 Volts TAPS: 2-2 1/2% ANFC and 2-2 1/2% BNFC

Primary Volts % Connect Leads to Tap No. 483 105 1 472 102.5 2 460 100 3 449 97.5 4 437 95 5 Secondary Volts 460 X1, X2, X3 266 X1 & X0, X2 & X0 1 phase X3 & X0

Primary

Connect Leads

Primary

Connect Leads to Tap No.

Volts

%

to Tap No.

Volts

%

604 589 575 561 546

105

1 2 3 4 5

242 236 230 224 219

105

1 2 3 4 5

102.5

102.5

100 97.5

100 97.5

PRIMARY: 460 Volts Delta SECONDARY: 230Y/133 Volts TAPS: 1-5% ANFC and BNFC

95

95

Secondary Volts 230

Secondary Volts 230

X1, X2, X3

X1, X2, X3

X1 & X0 X2 & X0 X3 & X0

133

X1 & X0 X2 & X0 X3 & X0

133

1 phase

1 phase

Primary Volts % Connect Leads to Tap No. 483 105 1 460 100 2 437 95 3 Secondary Volts 230 X1, X2, X3 133 X1 & X0, X2 & X0 1 phase X3 & X0

PRIMARY: 230 Volts Delta SECONDARY: 230Y/133 Volts TAPS: 1-5% ANFC and 1-5% BNFC

PRIMARY: 575 Volts Delta SECONDARY: 460Y/266 Volts TAPS: 1-5% ANFC and BNFC

PRIMARY: 460 Volts Delta SECONDARY: 230Y/133 Volts TAPS: 2-2 1/2% ANFC and BNFC

Primary

Connect Leads to Tap No.

Primary Volts

Connect Leads to Tap No.

Volts

%

%

241 230 218

105 100

1 2 3

604 575 546

105 100

1 2 3

95

95

Secondary Volts 460

Secondary Volts 230

X1, X2, X3

X1, X2, X3

Primary Volts % Connect Leads to Tap No. 483 105 1 472 102.5 2 460 100 3 449 97.5 4 437 95 5 Secondary Volts 230 X1, X2, X3 133 X1 & X0, X2 & X0 1 phase X3 & X0

X1 & X0 X2 & X0 X3 & X0

X1 & X0 X2 & X0 X3 & X0

266

133

1 phase

1 phase

13

toll free 800.334.5214

ACME ELECTRIC | www.hubbell.com/acmeelectric/en

Made with FlippingBook - Online Brochure Maker