2022 BURNDY Master Catalog
Compression Connections
Copper Compression — Terminal — Flex —One Hole Long Barrel, Belled End — No Inspection Window TYPES YA-TC-FXB, YAV-TC-FXB (Continued)
▲See Copper Flex Long Barrel Terminal Tooling Tables in this section for complete tool and die listing information.
Conductor
FigureDimensions
Wire Strip Length
Stud Hole Diameter (K)
Color Code
Die Index
Stud Size
Outside Diameter (OD)
Barrel Length (B)
Pad Width (C)
Overall Length (L)
Hole Spacing (E) & (F)
Hole Offset (N)
Pad Thickness (T)
Metric MM² ***
CatalogNumber
Code
Flex
#8 AWG #6 Sol #8 Sol
#8 AWG G,H,I,K,M DLO #6 AWG G,H,I,K,M, DLO #5 AWG G,H,I,K,M, DLO #4 AWG G,H,I,K,M, DLO #2 AWG G,H,I,K,M, DLO #1 AWG G,H,I,K,M, DLO 1/0 AWG G,H,I,K,M, DLO 2/0 AWG G,H,I,K,M, DLO 3/0 AWG G,H,I,K,M, DLO 4/0 AWG G,H,I,K,M, DLO 250 kcmil I,K,M, 262DLO 300 kcmil G,H,I,K,M, 313DLO
** 10
YA8CTC14FXB
Red 49 1/4
0.27
0.27
0.90 0.44 1.78
— 0.31
0.08
1
YAV6CTC10FXB
#8-#10 0.21
0.31
1.22 0.48 2.00
— 0.25
0.08
** 16
#6 AWG
Blue
7
YAV6CTC14FXB
1/4
0.27
0.31
1.22 0.48 2.12
— 0.31
0.08
1-5/16
YA5CTC14FXB
#5 AWG
— BLue
7
1/4
0.27
0.30
1.22 0.44 2.12
— 0.31
0.07
YAV4CTC10FXB YAV4CTC14FXB YAV4CTC516FXB YAV2CTC10FXB YAV2CTC516FXB YAV1CTC10FXB YAV1CTC516FXB YAV25TC10FXB YAV25TC516FXB YAV25TC38FXB YAV25TC12FXB YAV26TC38FXB YAV26TC12FXB
#8-#10 0.21
0.38 0.38 0.38 0.46 0.46 0.51 0.51 0.56 0.56 0.56 0.56 0.63 0.63
1.22 0.55 2.05 1.22 0.55 2.17 1.22 0.55 2.24 1.35 0.68 2.24 1.35 0.68 2.43 1.50 0.75 2.41 1.50 0.75 2.60 1.50 0.83 2.45 1.50 0.83 2.64 1.50 0.83 2.77 1.50 0.83 3.20 1.63 0.93 2.95 1.63 0.93 3.39
— 0.25 — 0.31 — 0.34 — 0.25 — 0.34 — 0.25 — 0.34 — 0.25 — 0.34 — 0.41 — 0.62 — 0.41 — 0.62
0.09 0.09 0.09 0.10 0.10 0.12 0.12 0.12 0.12 0.12 0.12 0.13 0.13
#4 AWG
— Gray
8
1/4
0.27 0.33
1-5/16
5/16
#8-#10 0.21
#2 AWG
35 Brown 10
1-7/16
5/16
0.33
#8-#10 0.21
#1 AWG
— Green 11
1-9/16
5/16
0.33
#8-#10 0.21
5/16
0.33 0.40 0.56 0.40 0.56
1/0 AWG
50
Pink
12
1-9/16
3/8 1/2 3/8 1/2
2/0 AWG
70 Black
13
1-13/16
YAV27TC12FXB
3/0 AWG
95 Orange 14 1/2
0.56
0.70
1.64 1.04 3.44
— 0.62
0.14
1-13/16
YAV28TC38FXB
3/8
0.40
0.77
1.77
1.14 3.19
— 0.41
0.14
4/0 AWG
— Purple 15
1-7/8
YAV28TC12FXB
1/2
0.56
0.77
1.77
1.14 3.63
— 0.62
0.14
YA30TC12FXB
— 250 kcmil G,H — Yellow 16 1/2
0.56
0.81
4.04 1.20 4.04
— 0.62
0.16
2-1/4
YA31TC12FXB
—
150 White 17 1/2
0.56
0.88
2.18
1.29 4.09
— 0.62
0.18
2-1/4
YA32TC12FXB
—
185 Red 18 1/2
0.56
0.95
2.32 1.40 4.28
— 0.62
0.19
2-1/4
** The MM 2 conductor size referenced here is for both Class 2 and Class 5 conductor *** The MM 2 conductor sizes listed are the recommendations for Class 5 conductor ♦ For applications greater than 2000 volts consult cable manufacturer for voltage stress relief instructions Notes: All dimensions shown are for reference only. Field bending straight lugs to achieve an angular connection will void UL Listing / CSA Certifications and BURNDY will not be liable for the connection.
1-800-465-7051 (Canada) 1-603-647-5299 (International)
C-101