2022 BURNDY Master Catalog

Small Terminals

Color-Coded Uninsulated Compression Parallel Splice

TYPE YSCM HYLINK™

Type YSCMHYLINK™ seamless parallel splice connectors permit stranded wires to be laid parallel inside the connector and spliced together withBURNDY ® compression tools. EachYSCMconnector accommodates awide range of conductors and is color coded to ensure proper tool and die match. YSCM connectors are cULus ListedWire Connectors per UL 486A/B. Additionally, they are cULus Listed for Grounding and Bonding per UL 467 and rated for direct burial in Earth and Concrete.

SEAMLESS TUBING

ELECTRO-TIN PLATED

BEVELED ENTRY

COLOR-CODE AND DIE INDEX

(TYPICAL INSTALLATION)

Conductor Range Cable‡

Dimensions Inches [mm]

Recommended Installation Tooling

Wire Strip† Length

Color Code

Die Index

Catalog Number

Circular Mils

L ±.03

O.D. ±.01 0.27 [7] 0.31 [8] 0.38 [10] 0.47 [12] 0.52 [13] 0.57 [14] 0.64 [16] 0.7 [18] 0.78 [20] 0.8 [21]

OUR840, 500, 600 Series

35, 750 Series

Min.

Max.

0.5 [13] 0.5 [13] 0.5 [13]

YSCM17

Red

49

X8CRT, W8CRT

U8CRT

11/16

13,060

16,910

YSCM27

Blue

7

X5CRT, W5CRT

U5CRT

11/16

16,910

26,890

YSCM42

Gray

8

X4CRT, W4CRT

U4CRT

11/16

29,970

41,520

0.62 [16] 0.62 [16] 0.69 [18] 0.81 [21] 0.81 [21] 0.88 [22] 1.05 [27]

YSCM66

Brown

10

X2CRT, W2CRT

U2CRT

3/4

42,750

66,040

YSCM80

Green

11

X1CRT1, W1CRT1

U1CRT1

3/4

67,980

80,020

YSCM104

Pink

12

X25RT, W25RT

U25RT

15/16

82,870 103,630

YSCM133

Black

13

X26RT, W26RT

U26RT

1-1/16

104,960 133,220

YSCM167

Orange

14

X27RT, W27RT

U27RT

1-1/16

134,340 166,560

YSCM212

Purple

15

X28RT, W28RT

U28RT

1-1/16

167,380 211,820

YSCM231

Yellow 16

X29RT, W29RT, *

U29RT

1-1/16

230,800 230,800

Notes: Material: Copper per ASTM B75. Finish: Tin plated. For nickel plating, add suffix “NK” to the Catalog Number. Dimensions in brackets [ ] are in millimeters rounded off to the nearest millimeter, unless otherwise noted, and are for reference only. †Recommended strip length. Strip length dependent on size, no. of wires and insulation thickness. ‡Refer to Circular Mil Table per ASTM B8 for total Class B Circular Mil calculations. *YSCM231 can also be installed with MY29-3 and retain Listings. Add the circular mils of the wires you wish to splice; that sumwould be used to determine the correct splice using the Min/Max columns on the table above. The tables to the right are for reference only.

Circular Mil Table per ASTM B8 Size

Circular Mil Table per ASTM B8 Size

ASTM Strandings

ASTM Strandings

Circular Mils 66,370 66,370 83,690 83,690 83,690 105,500 105,500 105,500 133,100 133,100 133,100 167,800 167,800 167,800 211,600 211,600 211,600

Cable Diameter (in)

Circular Mils

Cable Diameter (in)

AWG

Class

AWG

Class

2 2 1 1 1

AA

0.320 0.292 0.360 0.328 0.332 0.368 0.390 0.373 0.414 0.438 0.419 0.464 0.492 0.470 0.522 0.522 0.528

1,022 1,624

20 18 16 14 12 10

B B B B B B B B B B B

0.036 0.045 0.057 0.072 0.091 0.116 0.130 0.146 0.164 0.184 0.206 0.254 0.232 0.285 0.260

B & A

AA

A B

2,583 4,107 6,530 10,380 13,090 16,510 20,820 26,250 33,100 41,740 41,740 52,630 52,630

1/0 1/0 1/0 2/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0

A & A

-

B

A & A

9 8 7 6 5 4 4 3 3

-

B

A & A

-

B

AA

A & A

B & A

-

AA

B

B & A

1-800-465-7051 (Canada) 1-603-647-5299 (International)

B-59

Made with FlippingBook flipbook maker