2022 BURNDY Master Catalog
Small Terminals
Color-Coded Uninsulated Compression Parallel Splice
TYPE YSCM HYLINK™
Type YSCMHYLINK™ seamless parallel splice connectors permit stranded wires to be laid parallel inside the connector and spliced together withBURNDY ® compression tools. EachYSCMconnector accommodates awide range of conductors and is color coded to ensure proper tool and die match. YSCM connectors are cULus ListedWire Connectors per UL 486A/B. Additionally, they are cULus Listed for Grounding and Bonding per UL 467 and rated for direct burial in Earth and Concrete.
SEAMLESS TUBING
ELECTRO-TIN PLATED
BEVELED ENTRY
COLOR-CODE AND DIE INDEX
(TYPICAL INSTALLATION)
Conductor Range Cable‡
Dimensions Inches [mm]
Recommended Installation Tooling
Wire Strip† Length
Color Code
Die Index
Catalog Number
Circular Mils
L ±.03
O.D. ±.01 0.27 [7] 0.31 [8] 0.38 [10] 0.47 [12] 0.52 [13] 0.57 [14] 0.64 [16] 0.7 [18] 0.78 [20] 0.8 [21]
OUR840, 500, 600 Series
35, 750 Series
Min.
Max.
0.5 [13] 0.5 [13] 0.5 [13]
YSCM17
Red
49
X8CRT, W8CRT
U8CRT
11/16
13,060
16,910
YSCM27
Blue
7
X5CRT, W5CRT
U5CRT
11/16
16,910
26,890
YSCM42
Gray
8
X4CRT, W4CRT
U4CRT
11/16
29,970
41,520
0.62 [16] 0.62 [16] 0.69 [18] 0.81 [21] 0.81 [21] 0.88 [22] 1.05 [27]
YSCM66
Brown
10
X2CRT, W2CRT
U2CRT
3/4
42,750
66,040
YSCM80
Green
11
X1CRT1, W1CRT1
U1CRT1
3/4
67,980
80,020
YSCM104
Pink
12
X25RT, W25RT
U25RT
15/16
82,870 103,630
YSCM133
Black
13
X26RT, W26RT
U26RT
1-1/16
104,960 133,220
YSCM167
Orange
14
X27RT, W27RT
U27RT
1-1/16
134,340 166,560
YSCM212
Purple
15
X28RT, W28RT
U28RT
1-1/16
167,380 211,820
YSCM231
Yellow 16
X29RT, W29RT, *
U29RT
1-1/16
230,800 230,800
Notes: Material: Copper per ASTM B75. Finish: Tin plated. For nickel plating, add suffix “NK” to the Catalog Number. Dimensions in brackets [ ] are in millimeters rounded off to the nearest millimeter, unless otherwise noted, and are for reference only. †Recommended strip length. Strip length dependent on size, no. of wires and insulation thickness. ‡Refer to Circular Mil Table per ASTM B8 for total Class B Circular Mil calculations. *YSCM231 can also be installed with MY29-3 and retain Listings. Add the circular mils of the wires you wish to splice; that sumwould be used to determine the correct splice using the Min/Max columns on the table above. The tables to the right are for reference only.
Circular Mil Table per ASTM B8 Size
Circular Mil Table per ASTM B8 Size
ASTM Strandings
ASTM Strandings
Circular Mils 66,370 66,370 83,690 83,690 83,690 105,500 105,500 105,500 133,100 133,100 133,100 167,800 167,800 167,800 211,600 211,600 211,600
Cable Diameter (in)
Circular Mils
Cable Diameter (in)
AWG
Class
AWG
Class
2 2 1 1 1
AA
0.320 0.292 0.360 0.328 0.332 0.368 0.390 0.373 0.414 0.438 0.419 0.464 0.492 0.470 0.522 0.522 0.528
1,022 1,624
20 18 16 14 12 10
B B B B B B B B B B B
0.036 0.045 0.057 0.072 0.091 0.116 0.130 0.146 0.164 0.184 0.206 0.254 0.232 0.285 0.260
B & A
AA
A B
2,583 4,107 6,530 10,380 13,090 16,510 20,820 26,250 33,100 41,740 41,740 52,630 52,630
1/0 1/0 1/0 2/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0
A & A
-
B
A & A
9 8 7 6 5 4 4 3 3
-
B
A & A
-
B
AA
A & A
B & A
-
AA
B
B & A
1-800-465-7051 (Canada) 1-603-647-5299 (International)
B-59